    Nordyne Propane Furnace - no heat
    I have a Propane furnace model # KG6RC-060C-12A. The furnace fires up but shuts off after a few seconds. It attempts this 3 times and then shuts off. The code light is blinking 4 times. I checked the wiring for loose grounds and it appears to be OK. The unit is only 3 years old. Any suggestions on what it could be or how I should proceed?
    realredwood's Avatar
    realredwood Posts: 2, Reputation: 1
    New Member
     
    #2

    Feb 1, 2010, 10:07 AM
    Nordyne Propane Furnace
    I have a Propane furnace model # KG6RC-060C-12A. The furnace fires up but shuts off after a few seconds. It attempts this 3 times and then shuts off. The light is blinking 4 times. I checked the wiring for loose grounds and it appears to be OK. The unit is only 3 years old. Any suggestions on what it could be or how I should proceed?
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #3

    Feb 1, 2010, 10:35 AM
    Try cleaning the flame sensor with fine sandpaper or steel wool.
    Attached Images
      
    Dennisjr's Avatar
    Dennisjr Posts: 1, Reputation: 1
    New Member
     
    #4

    Oct 20, 2011, 05:38 AM
    Red light
    On = Power
    1 Flash = Limit Circuit Open or External Load on "W"
    2 Flashes = Pressure Switch is Open with Inducer ON
    3 Flashes = Pressure Switch is Closed with Inducer OFF
    4 Ignition Failure( Check ground)
    Continuous blink= False Flame or Gas Valve Relay Shorted

    Yellow Light
    On= Flame Present
    Continuous flash= Low Flame Sensor Signal


Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Nordyne Heat Furnace Blower [ 5 Answers ]

I have a Nordyne heater in a 1996 mobile home. My A.C. works normal. I can also switch the blower to ventilate and it works normal. But, when I switch the thermostat to heat. The blower will not come on. I can see the furnace heating up, but that it. According to the diagram, this unit does...

Nordyne heat pump high suction in heat [ 1 Answers ]

I have a 2 yr old heat pump.in heat mode at 40 deg outside I have 120 psi on the suction and 160 psi on the disc. 99 deg. At discharge from condenser.first season for heat.sounds like a stuck or leaking reverse valve. Any suggestions. Thanks ps I tried switching from air to heat a few times

Advantages of converting from propane heat to electric heat for home use [ 1 Answers ]

When is it an advantage to convert from propane heat to electric heat in a residential home? Also could you give me a rough idea of what it costs to make this transition? Thank you. :confused:

Nordyne air&heat [ 2 Answers ]

Wireing diagram for thermostat&heat strips 1-5kw 1-10kw

Heat pump vrs propane furnace [ 1 Answers ]

I live in Indianapolis, IN area and am building a 92'x52' building with 3 heat elements. I was wondering if the air flow heat pump would be efficient in tis area?