    Greetings, I have an Intertherm M2RC furnace running on LP. I tried to start it up a couple of weeks ago, it ran for a second then quit. The furnace is getting power, but the red LED indicator light is not lighting. With cold weather just a couple of weeks out, I could use some help.

    Thanks
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Sep 5, 2007, 03:19 PM
    First try a reset. Turn power completely off to the unit and then back on. If that fails check to be sure you have LP gas in the tank. Also check to be sure you inducer fan ( the little fan that puts air into the combustion chamber is running.) You might also have a spider web in the orfice in the burner.

    The next usually takes a professional to check especially with LP. The below list of parts are expensive so you might want to have someone service your unit before you just replace the parts.

    632316 FLAME SENSOR INTERTHERM Stk $16.80
    624610 GAS VALVE (M1M) INTERTHERM Stk $132.37
    626422 SWITCH.LIMIT ROLLOUT-155 DEG. INTERTHERM Call $9.03
    632252 PRESSURE SWITCH M2 1.74 INTERTHERM Stk $27.90
    903106 CONTROL, INTEGRATED G4,5,6 INTERTHERM Stk $206.46
    626461 LIMIT,INDUCER FAN (160 F) INTERTHERM
    902977 INDUCER REPLACEMENT KIT(FASCO) INTERTHERM Stk $203.67
    labman's Avatar
    labman Posts: 10,580, Reputation: 551
    Uber Member
     
    #3

    Sep 5, 2007, 04:50 PM
    If the red light isn't on, likely the little blade fuse on the control board is blown.
    The transformer could be bad too.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

My intertherm furnace pilot lights but furnace won't kick on [ 5 Answers ]

I need some diagnostic help. We have a full propane tank. A new burner plate (last year) and the blower works. We light the pilot but the knob should pop up after one minute thus lighting the furnace. It won't pop up. What part should we replace? The furnace is a 17 year old Intertherm MGH...

Intertherm furnace [ 1 Answers ]

I own a 1985 modular home and the intertherm blower fan on my furnace quit working is it too hard to fix or change?:confused: Also what is the cost to fix it?:eek: Please help!! :) Thank you Rachell

Intertherm Furnace [ 1 Answers ]

My pilot light comes on and ignites heat exchanger but when the cover closes the flames shut down. The blower works but heat exchanger will not stay lit. I have replaced the gas valve and the thermo couple. Suggested that damper valve needed to be adjusted - where is the damper valve


View more questions Search