    No heating, only hot water
    Hi there

    I have a combi bolier which produces water and heating (via water radiators) from mains water supply.

    Last year the radiators in my central heating system worked just fine.

    My hot water still works fine.

    I tried to turn my heating on a week ago, the radiator nearest the boiler (and to a far lesser extent the one next to it) became luke warm in the lower portions. The rest of the radiators remained stone cold.

    I decided to bleed the radiators. The first radiator (which had produced some heat) emitted a tiny amount of air and oily water.

    When bleeding the second radiator, only clear water came out. However, the nut in the radiator came out completely, and due to the pressure of the water, I could not stop the flow of water out of the radiator until the mains supplies were shut off. This meant that I lost over a bucket of water from the system.

    Now zero heat is generated from any of my radiators my central heating system but my hot water remains OK.

    When I switch my central heating on, the bolier displays an orange light, which shows that the central heating control switch and radiators are requesting heat (the same orange light shows when I run the hot water tap). The problem is that the light only stays orange for less than 30 seconds before going out. This means that the boiler is not being told to produce heat.

    I would really appreciate it if anyone can advise what to do next before I call in the professionals?

    Many thanks

    Sarah
    NorthernHeat's Avatar
    NorthernHeat Posts: 1,455, Reputation: 132
    Ultra Member
     
    #2

    Nov 1, 2006, 03:16 PM
    Combi boilers can be hard to diagnose for a service tech standing in front of the unit. Could be a weak flame sensor signal, does burner stay lit. Could be air in the system, many codes require a low water cut off, of a flow sensor if pump isn't moving water. That could be a bad pump or vapor lock. Did any valves get closed. Water has to flow through the primary loop for domestic water to get hot, but doesn't mean water is flowing through the heating loop.

    Sorry, best I can do with what you have said.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Hot water heating system [ 3 Answers ]

Thans for your help in adavance, I have a hot water heating system boiler with a red pump at the side of the boiler. I would like to know does the pump pushes the water through the System.or pull the water back to the boiler.:rolleyes:

No Hot Water to shower head, but Hot water to the Tub? [ 2 Answers ]

My husband and I just purchased a new house. We have found that the shower pressure in the bathroom is wonderful however once you have set the right temp from the tub spout and switch over to the shower no hot water makes it to the shower head. We can only turn off the cold water completely in...

Replacing Hot Water Radiators with Hot Water Baseboards [ 2 Answers ]

I have a hot water heating system with radiators, and I want to replace the radiators in the upstairs bathroom and bedrooms (2) with hot water baseboards. Can radiators and baseboards be mixed and if so, how do I determine the size of the baseboards?

Warm radiators when the heating is off, and hot water is on [ 0 Answers ]

Please Help, Does anyone know what the problem is with my central heating system. The radiators in the house are warm, but I have not been calling for central heating, only water. Radiators are warm both upstairs and down. I have a gas fired boiler down stairs in the kitchen and hot water...

Blocked central heating hot water pipe [ 2 Answers ]

Hi, Hope someone can help me out. A brief senario: the hot water comes out of the boiler and then goes through a pump. After this it get split up 2 ways (1) to the radiators which are hot, working and not the problem. (2) The problem path is through a hot water to water heat exchanger tank...


View more questions Search