    Hi everyone. I currently have a hunter thermostat that's digital but am replacing it with a newer honeywell rth5100b. Here's my question:

    The old thermostat has the standard 4 R G W Y terminals with their respective wires connected to them. However, there is a 5th wire ( blue in this case) connected along with the red to the R terminal. When looking at the wiring at the fan control, it appears that the blue wire is connected to the left most TH terminal on the gas valve and to nothing else. All other wiring seems to match up, its just this blue wire.

    Should I just match the old thermostat with respect to the wiring?
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Sep 23, 2007, 09:44 AM
    I would hook them up the way they came off. Unless you feel like tearing the wiring apart to find out exactly what they are doing.
    acetc's Avatar
    acetc Posts: 1,004, Reputation: 79
    Ultra Member
     
    #3

    Sep 23, 2007, 12:10 PM
    If you have an older furnace, this blue wire may be to relite the pilot if it should go out , they did this on older furnaces with a standing pilot but normally would connect it to the "B" terminal which is made when there is a call for heating, by connecting it to the "R" terminal it would relite the pilot any time the pilot goes out, not just in the heating mode.
    ryant's Avatar
    ryant Posts: 2, Reputation: 1
    New Member
     
    #4

    Sep 23, 2007, 07:34 PM
    The furnace is from aprox 1984 or so. However in 1990 or so central air was added. Since the R terminal supplies 24V I'm assuming this was just some wacky way the installer decided to connect the TH terminal. The middle terminal of the gas valve has a white wire, connected to the W terminal on the fan control, and then off to the thermostat of course. There is also a 2-wire thermostat cable going to the compressor for the a/c, one wire connected to Y at the fan control which makes sense and the other is connected to the C terminal on the control (I guess this is just a way for them to get 24V to the ceompressor.


    Oh and the gas valce is a white-rogers 36c03 type 241 gas valve. The furnace itself is an ICG which I believe is essentially keep rite now. The fan control is made by honeywell.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Thermostat Wiring - From Two to One Thermostat [ 4 Answers ]

Currently my central a/c unit is hooked up to a Honeywell CT3500 Programmable Thermostat. I've noticed that the thermostat can handle heat as well as cooling. My furnace is hooked-up to an older manual thermostat. It is a simple 2 wire set-up - red & white. Could the furnace be hooked-up to the...

Thermostat wiring [ 2 Answers ]

I had an older honeywell thermostat and I wanted to change it to a programmable one. I have a multistage heat pump. I have 6wires coming out of the wall, that are not labeled and can get my ac or heat to work. I did purchace a RTH7400 thermostat that is by honeywell. My wires are red, pink, orange,...

Wiring a new Thermostat [ 1 Answers ]

I want to change an old Honeywell thermostat (connected to a General Electric Heating & Cooling device) by a new one (Meitav ERT100-LC) There are 6 wires available in the wall with the following colors: ------------------------------------------------------------------------ Red, Brown, ...

Wiring a thermostat [ 1 Answers ]

Recently bought a house. It has forced hot air and I want to replace my old honeywell stat with a new honeywell stat. the wire has four colors red,black,yellow and green. I've never seen anything like this before. Usually the wire has 3 or 5. so I thought it was going to work, but the stat has only...

Thermostat Wiring Help [ 2 Answers ]

I'm new to putting in a thermostat or working on anything like this, so please bear with me. I really appreciate any help you can give me with my problems. Ok, I have a thermostat that has only three wires attached to it. It has a red wire, a black wire, and a white wire. I have no clue ehat...


View more questions Search