    Miller trailer furnace problem
    :confused: I have a Miller oil furnace in my garage that burns very dark orange and sooty. It also keeps burning inside after the unit shuts down. I have replaced the nozzle twice with no change. The flue from the top of the unit all the way through the roof is clear.
    Any ideas??
    rickdb1's Avatar
    rickdb1 Posts: 185, Reputation: 15
    Junior Member
     
    #2

    Sep 14, 2006, 05:58 AM
    Are you sure that you have adequate combustion air? Try opening the door a bit and see if it burns cleaner... A garage is considered an enclosed area and must have outside combustion makeup air...
    chillytoolman's Avatar
    chillytoolman Posts: 2, Reputation: 1
    New Member
     
    #3

    Sep 14, 2006, 06:37 AM
    I'm sorry I wasn't more clear... I should have said barn or maybe even wind-tunnel, it even does this with the big door open
    Thanks anyway for your time
    rickyburneechi's Avatar
    rickyburneechi Posts: 1, Reputation: 1
    New Member
     
    #4

    Feb 24, 2009, 12:18 PM
    I'm assuming it's a 3450 rpm burner?
    How are the primary air bands on the burner set? Perhaps they are not open as much as they should be?
    Is the condition of the combustion chamber OK? There might be something in front of the air tube causing impingement.
    Is the furnace sooting?
    There may be something wrong with the end of the air tube causing the problem. It could be cracked, burned away.
    What is the pump pressure? Is the nozzle cutoff portion of the pump OK? If not, the oil will leak into the chamber after shut down and burn.
    Perhaps the nozzle is too large or has the incorrect pattern for the combustion area.
    leadbottom's Avatar
    leadbottom Posts: 1, Reputation: 1
    New Member
     
    #5

    Sep 30, 2009, 04:44 AM
    Wireing the buzz fuse it has 2 red wires 1 has black writeing on it every time I connect it the fuse pops white two white black two black can any 1 help me

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Bryant furnace problem [ 20 Answers ]

Hi All, I have a 5 y/o 80% eff bryant furnace. The problem I have is that my furnace Doesn't always kick on even when thew thermostat shows the temp under the Temp set. I will sometimes have to go down and turn of the blower switch on the furnace wait a couple seconds and then turn it on again....

Furnace with Generator problem? [ 27 Answers ]

I have a York Two-Stage Deluxe Diamond (PDU) furnace that I have recently wired to a 6 CKT transfer switch (Reliance Controls) to use with my Coleman 6250 (5000watt) gas generator. All my ckts. Work well with the generator connected, except the furnace. I switched ckts on the transfer switch-no...

Trane Gas Furnace Problem [ 13 Answers ]

I recently experienced a problem with my heat. I have a programmable thermostat and noticed that the heat wasn't on when it was suppose to be. The temperature was set to 75 but the temperature in the room was only 68. I canceled the program and manually set the temperature again to 75. The heat...

Glenn Miller [ 1 Answers ]

I need to know what the song is that plays during the opening credits of "The Glenn Miller Story".

The Glenn Miller Story [ 1 Answers ]

What is the song that plays during the opening credits of "the glenn miller story". Could someone please fndout?


View more questions Search