    Loud Bang when AC turns on or off
    My wife and I have noticed a loud bang (can hear it anywhere in the whole house) every time our AC kicks on, or shuts down. It is a relatively new sound (just noticed it this spring). I'm pretty sure it was not making this sound ever in the past. This is different than the audible click that I've always heard near the thermostat when the system turns on and off.
    Any ideas what is making the loud bang, and how to fix it?
    siberianair's Avatar
    siberianair Posts: 360, Reputation: -4
    Full Member
     
    #2

    Jul 24, 2009, 03:35 PM

    Is the ac working OK otherwise? Loud bangs can come from several sources. Fan, compressor, wiring issues, capacitor issues, refridgerant issues.
    Being it is at start and stop I would guess something with your compressor is the issue.
    holmbino89's Avatar
    holmbino89 Posts: 3, Reputation: 1
    New Member
     
    #3

    Jul 24, 2009, 04:05 PM

    Other than the loud bang, it seems to work just fine. It maintains a temperature nicely. Turns on quickly. Easily distributes cold air around the house. Etc.
    siberianair's Avatar
    siberianair Posts: 360, Reputation: -4
    Full Member
     
    #4

    Jul 24, 2009, 04:10 PM

    I would have a tech come look at it. That way they can hear the bang and try to diagnos from there.
    There could be multiple things going on..
    wmproop's Avatar
    wmproop Posts: 3,749, Reputation: 91
    Ultra Member
     
    #5

    Jul 24, 2009, 06:01 PM
    Does it do it in heat mode?
    Try with ac and heat off, and turn tstat to fan/fan only setting, does it still make the big bang?
    hkstroud's Avatar
    hkstroud Posts: 11,929, Reputation: 899
    Home Improvement & Construction Expert
     
    #6

    Jul 24, 2009, 07:34 PM

    The bang you hear is the compressor motor hitting the side of the can it is in. The actual motor is inside of the sealed can that you see. The motor sits on four springs. That's why you don't feel much vibration when it is running. One of the springs has broken.

    Now when the motor starts or stops it hits the side of the can. Nothing you can do about it. May run for a day or may run for 5 years or more. Mine has been doing that for about 5 years.
    T-Top's Avatar
    T-Top Posts: 1,871, Reputation: 100
    Ultra Member
     
    #7

    Jul 24, 2009, 08:03 PM
    If you have a dirty return air filter you may be hearing the duct work popping. If it's a sound only on startup and shut down, with the info you gave it sounds like your return duct is popping.
    wmproop's Avatar
    wmproop Posts: 3,749, Reputation: 91
    Ultra Member
     
    #8

    Jul 24, 2009, 08:19 PM
    If he can hear it anywhere in the house,I would guess the sound is coming through the duct work,, my thoughts also T-Top but ,maybe not
    siberianair's Avatar
    siberianair Posts: 360, Reputation: -4
    Full Member
     
    #9

    Jul 25, 2009, 05:02 AM
    Quote Originally Posted by hkstroud View Post
    The bang you hear is the compressor motor hitting the side of the can it is in. The actual motor is inside of the sealed can that you see. The motor sits on four springs. That's why you don't feel much vibration when it is running. One of the springs has broken.

    Now when the motor starts or stops it hits the side of the can. Nothing you can do about it. May run for a day or may run for 5 years or more. Mine has been doing that for about 5 years.

    Most compressors sit on rubber rings in the middle of the condenser not springs. The rings are replaceable. And no the compressor can't just hit the side of the unit on 98% of most units.
    I do wonder if the sound is coming from the outside or inside. I was tired from a long week and did not think to ask that.
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #10

    Jul 25, 2009, 01:24 PM
    ((most compressors sit on rubber rings in the middle of the condensor not springs. the rings are replaceable. and no the compressor can't just hit the side of the unit on 98% of most units.
    i do wonder if the sound is coming from the outside or inside. i was tired from a long week and did not think to ask that. ))


    All tin can style motor compressors have internal spring mounts to support the motor/pump assembly. There are many reasons the manufactures started using spring mounts over the past 50 years but the main reason was to absorbe the motor starting torque and tp prevent internal damage to the internally attached pumping assembly.

    Exploded view of compressor below

    Air Conditioning and Refrigeration - Google Books


    See item 7 below

    http://202.56.127.90/nacg/EnggRec/En...endation16.pdf


    And well answered by someone other than me.

    The compressor you see is actually the outer shell, inside of which is a refrigerant pump (ie:compressor) which is on internal support springs. When the unit turns off, the momentum of the internal parts can sometimes knock against the outside of the compressor case. The only "fix" would be a new compressor. In the real world, the fix is to live with it. It's generally not an indication of immenent compressor failure and most likely will run many more years with no problem. Note: if you put your hand on most compressors (even new unused ones) and give them a shake, you will hear that noise.
    siberianair's Avatar
    siberianair Posts: 360, Reputation: -4
    Full Member
     
    #11

    Jul 25, 2009, 06:30 PM

    See I was so tired I was thinking about the compressor and not the insides of one...
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #12

    Jul 25, 2009, 06:35 PM
    I understand. Mr. Tired and myself go back a long way. LOL

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Check valve making a loud bang at end of cycle [ 15 Answers ]

I just replaced my sump pump because the old one would not shut off and it was 8 years old. I had to replace the pvc piping coming out of the pump that comes up and out of the pit. I did not drill a 'relief hole' in the new pipe(the old pipe had one), could this be causing excess pressure that is...

Toilet makes a loud BANG after being flushed [ 7 Answers ]

Hello - I think I have water hammer but I an unclear as to how to fix it! I live in a 16 year old house, and every time I flush one of the toilets upstairs it flushes fine but when finished filling, it makes a very loud bang! I don't want any problems with pipes, so I am wondering how to fix this? ...

Loud bang in the basement after flushing the toilet [ 7 Answers ]

After I flush the toilet and the water went down the drain, a few moments later I hear a loud banging noise from the basement. I did some reading and it is suggested that I may have a water hammer. However the water hammer is normally associated with a closing valve which is not the case here. The...

Bang noise after furnace turns off [ 7 Answers ]

Dear Expert: I have a new Carrier 2-stage 80% efficiency furnace in my home. Lately I heard big bang noise every time about 20 seconds after the furnace shuts off. It sounds scary to me since I don't know what's wrong? :eek: Does anyone have hint about what it is and how to solve it?...

Bronco stopped moving with loud bang [ 2 Answers ]

It sounded like I ran over a huge pothole but then the Bronco stopped moving and stalled. I turned the key off and opened the hood thinking maybe I blew something, but it all looked normal. I turned the key back on and it started right away. Moving the truck to drive however didn't cause the...


View more questions Search