Lennox ac unit on, but fan not running
We have a lennox ac unit less than 5 yrs old. The furnace will turn on, and it feels like cooler air coming out of the vents, but when you check actual unit outside, the fan is not running. The top gets very hot when its trying to run, and its making a humming noise, but no fan movement. Any ideas?
|
|
 |
Ultra Member
|
|
Jun 22, 2010, 08:39 PM
|
|
Take a stick,try to force spin the fan, does it start up? Is it a little hard to spin with the stick?is the compressor running?
|
|
 |
New Member
|
|
Jun 24, 2010, 10:35 AM
|
|
The fan started running when I moved with screwdriver, and the fans inside are now blowing, but its not really sending out any cool air.
|
|
 |
New Member
|
|
Jun 24, 2010, 12:50 PM
|
|
Also now the fan won't stay running
|
|
 |
Ultra Member
|
|
Jun 24, 2010, 04:28 PM
|
|
When you turn it with screwdriver/stick does it move freely or does it have some resistance?
|
|
 |
New Member
|
|
Jun 24, 2010, 05:36 PM
|
|
Yes moves freely
|
|
 |
Home Repair & Remodeling Expert
|
|
Jun 24, 2010, 07:08 PM
|
|
Your outside unit is a compressor and a fan drawing air across the coils. Sounds like your compressor may be running but without that fan its going to fry. You may have a bad capacitor in the fan motor which is not very expensive or difficult to fix or you could just buy a new fan motor. I'd disconnect and remove the fan and try bench testing it before doing much else.
|
|
 |
New Member
|
|
Jun 24, 2010, 08:09 PM
|
|
How would you bench test? An hour ago the upstairs unit (which is the one with the problem) tripped the breakers for the downstairs unit, and now both are not working.
|
|
 |
Home Repair & Remodeling Expert
|
|
Jun 24, 2010, 08:32 PM
|
|
Bench testing would involve having the motor only on a work bench and apply direct 120 vac to the hot and neutral leads from the motor. If it still won't spin replace the capacitor, still no spin buy a new motor. You were using outside/inside to describe your units, lets stick with that. This is a Lenoox furnace with AC, right? The outside is your compressor and fan for cooling coils. Inside is your furnace for heat, A coil and fan for cooling. You should not let one unit run if the other unit is in failure. The power appears to be off but double check that nothing is still hot. Don't want you opening the outside cage with power still on anywhere
|
|
 |
Ultra Member
|
|
Jun 24, 2010, 08:44 PM
|
|
 Originally Posted by jennalou924
We have a lennox ac unit less than 5 yrs old. The furnace will turn on, and it feels like cooler air coming out of the vents, but when you check actual unit outside, the fan is not running. the top gets very hot when its trying to run, and its making a humming noise, but no fan movement. Any ideas?
At less than 5 years old,the motor should be under warranty,check into it but keep in mind and ask what the labor fees might be, something to think about also doing it yourself could/might void the warranty
|
|
Question Tools |
Search this Question |
|
|
Add your answer here.
Check out some similar questions!
My outside Lennox A/C unit not coming on, fan runs, but nothing else.
[ 12 Answers ]
Hi! My outside Lennox A/C unit (approx. 4 years old) is not coming on. The fan will run, if we start it manually (spin it ourselves) and will continue to run of its own accord. But the motor(?) or compressor or condenser or something in there will not turn on, it tries, but to no avail. Also, we...
Outside AC Unit Making BUZZ Noise but Fan not running!
[ 6 Answers ]
I noticed that my outside AC unit is making a buzzing noise and the fan is not running. Of course, this is also NOT making the home cooler. Currently, I am running the second AC unit for upstairs and using fans to survive. What can be this problem?
AC Unit Cooling Fan Not Running
[ 5 Answers ]
Hi. My son's HVAC unit is an older Carrier model and needs replaced, but he is trying to limp through this summer until he can afford to buy a new one.
The problem is the cooling fan will not run in the outside unit. I took a look at it and the contactor is pulling in and the compressor is...
A/C unit fan stays running
[ 2 Answers ]
The FAN on the air conditioner unit on top of my house stays running all the time.
The unit cools when it is supposed to, however when it's reached the room's temp, and the house thermostat automatically shuts of the unit, the fan staysd on. It even stays on when the slide switch on the thermostat...