Ask Experts Questions for FREE Help !
Ask
    BrianPowley's Avatar
    BrianPowley Posts: 1, Reputation: 1
    New Member
     
    #1

    Oct 1, 2009, 08:03 AM
    Kenmore 90 Furnace goes into lockout
    My furnace is a Sears Kenmore 90 (Propane)
    The info on the placard inside the cabinet is:
    MFG.: HQCD (I believe it to be a TempStar)
    Model: NULK125DK03867
    Mfr. No.:NULK125DK03
    The problem:
    Thermostat calls for heat
    The ID fan starts and I've inspected the vent and there is air being blown outside.
    The blower motor starts
    The hot surface igniter glows cherry red.
    After about 20 seconds, the igniter shuts off.
    The burners never produce any flame.
    The system cycles 3 more times and then the LED glows solid red or Lockout.
    It appears as if everything is OK except for opening the gas valve.
    The propane tank is at 80%
    The flame sensor was replaced last heating season.
    Any way to test the controller to see why the gas valve doesn't open?
    Or??
    T-Top's Avatar
    T-Top Posts: 1,871, Reputation: 100
    Ultra Member
     
    #2

    Oct 1, 2009, 06:29 PM
    You have one of the 5 or all: dirty burners, no gas(shut off some where), low gas pressure, no 24 volts going to gas valve or bad gas valve. You should hear click at the gas valve about 10 to 15 sec after the hot surface igniter starts to glow.
    hvacservicetech_07's Avatar
    hvacservicetech_07 Posts: 1,083, Reputation: 75
    Ultra Member
     
    #3

    Oct 1, 2009, 08:04 PM

    I agree. Remove the burners, check for rust around the front of the burners not allowing the gas to pass through.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Furnace lockout [ 1 Answers ]

I have a Bryant furnace model 394GAZ036100. The problem I am having is intermitant. Furnace will run fine sometimes 6-8 hr, cycles OK and then doesn't start up on calling for heat. If I shut of power and turn it back on it will start and cycle OK. Never has messed up while I am sitting there...

Gas furnace lockout [ 1 Answers ]

My gas furnace will light, but then the flame goes away within a few seconds. It does this several times and then the LED light blinks six times which the sticker on the furnace indicates means a system lockout. What can I do to repair this?

Gas Furnace Lockout Timer [ 1 Answers ]

I have a Carrier gas furnace that I believe has a bad lockout timer. The furnace will sometimes run sometimes run then shut off and other times run fine. When it would suddenly stop I tapped on the lockout timer and it ran again, that makes me feel the lockout timer is bad but now when the...

Coleman Gas Furnace Lockout [ 2 Answers ]

I have a Coleman Evcon gas furnace in my garage, and when the temperature outside gets extremely cold (like 14 deg right now) the furnace will lockout and not re-light. The garage door is pretty shot, so this furnace has been exposed to the elements for a number of years... I have had a...

Carrier Furnace Limit Circuit Lockout [ 1 Answers ]

My Carrier Furnace is continuously blowing and the heat doesn't work. The code was first, Limit Circuit Fault, tnen after changing the filter, it went to Limit Circuit Lockout -- and it is still blowing cold air. (Yikes!! It got down to 10 degrees outside)


View more questions Search