Dec 30, 2009, 09:29 PM
|
|
Intertherm furnace
My intertherm furnace comes on but, sometimes it will shut off and sometimes it stays on until I have to turn the breakers off. What do you think is wrong? Thanks
|
|
 |
Ultra Member
|
|
Dec 30, 2009, 10:05 PM
|
|
Model #? Gas, fuel oil, or electric heat? When the unit "stays on", is it heating or just blowing cool air?
|
|
 |
New Member
|
|
Dec 31, 2009, 04:34 AM
|
|
Model# E2EB012, electric, heating
|
|
 |
Heating & Air Conditioning Expert
|
|
Dec 31, 2009, 05:23 AM
|
|
Sounds like a possible sticking heat sequencer. Try good old KC13's trick and hit it with the plastic end of a screw driver when it is stuck and see if it shuts off. They usually look like this in the Coleman line and if it does shut off proving the sequencer as defective replace it after turning off all the power breakers to the furnace. Make sure to mark all the wires to the sequencer so you can reinstall them correctly.
|
|
 |
New Member
|
|
Dec 31, 2009, 05:46 AM
|
|
I have replaced the sequencer and the relay but still have the same problemm
|
|
 |
Heating & Air Conditioning Expert
|
|
Dec 31, 2009, 07:14 AM
|
|
Then you better be checking the sequencer or relay for proper operation since these are the controls for the furnace. Just because you replaced the parts with new parts do not automatically mean they a good. The only other thing it could be woruld be a intermittent short in the thermostat wires OR a real reach is a defective thermostat.
Next time it does not shut off disconnect the W and RH wires off the terminal strip in the inside unit. That will remove the thermostat and thermostat wiring from the circuit. If it shuts off then the problem is in the thermostat wiring or thermostat.
|
|
 |
New Member
|
|
Dec 31, 2009, 08:19 AM
|
|
I already thought about the tstat and disconnected W and RH wires but it did not shut off. I just went on line and ordered an original replacement sequencer to replace this "generic" one the local parts place had to offer! That should fix it. Thank you so much for your help and time! Kevin
|
|
 |
Heating & Air Conditioning Expert
|
|
Dec 31, 2009, 11:35 AM
|
|
Make sure you follow/check your furnaces wiring diagram when installing the new one.
|
|
Question Tools |
Search this Question |
|
|
Add your answer here.
Check out some similar questions!
My intertherm furnace pilot lights but furnace won't kick on
[ 5 Answers ]
I need some diagnostic help. We have a full propane tank. A new burner plate (last year) and the blower works. We light the pilot but the knob should pop up after one minute thus lighting the furnace. It won't pop up. What part should we replace? The furnace is a 17 year old Intertherm MGH...
Intertherm furnace
[ 6 Answers ]
Hi I have a Intertherm Model MMHA 070ABHr-01 gas. Had a tech out replaced the ignitor/and adjusted it. Problem still is furnace calls for heat prepurge fan motor kicks?? In, ignites runs for 2-3 minutes kicks out fan motor starts runs for 30 sec shuts off. In the mean time the furnace has...
Intertherm furnace
[ 2 Answers ]
I have just in the last month had an Intertherm furnace installed, and since installation they have had to come in twice because they claim the starter button is not firing. They replaced it and now it is on the fritz again. It starts for about 8 seconds and cuts out. There is fuel in the tank....
Intertherm Furnace
[ 1 Answers ]
My pilot light comes on and ignites heat exchanger but when the cover closes the flames shut down. The blower works but heat exchanger will not stay lit. I have replaced the gas valve and the thermo couple. Suggested that damper valve needed to be adjusted - where is the damper valve
View more questions
Search
|