Installing a programmable thermostat away from gas fireplace
I have a gas fire place with a simple on off button on the fireplace face. I purchased a Honeywell programmable thermostat but I am a bit perplexed with the wiring. I have done some research regarding this matter and found a post indicating the two wire connections are the TH/TP to R and TH to the W.
I have two questions...
1. In a standard furnace installation, there are at least 5 wires. Is this lack of connections, going to cancel out some functions? i.e. programmable function? And if so, are there other wires I should look for to fill these connections?
2. Am I safe to run new wire from the fireplace front to a different location in the room? Just add onto it?
Thanks,
Nan
:o
|
|
 |
Heating & Air Conditioning Expert
|
|
Oct 12, 2008, 02:24 AM
|
|
I have a gas fire place with a simple on off button on the fireplace face
Unless the fireplace was originally designed for a Honeywell thermostat it will not work without some adapting. There is more to a thermostat operation besides hooking up wires. Low voltage power supply of the correct voltage 24 volts,separate isloation relays and a common wiring link that is the standard of the heat and A/C industry.
You might be able to get the thermostat part to work but you will need to
Check voltage present at the fireplace and see if it is compatible with the thermostat.
Add a isloation relay that the thermostat will trigger the fireplace from etc.
If you have a wiring diagram of the fireplace it will make it easier to figure out.
I also believe that I would contact the fireplace manufacturer and check with them to see if this (added thermostat/wiring etc) will violate the UL/CSA listing on that unit.
Since I have no wiring diagram available I can be of no further assistance. Sorry
|
|
 |
New Member
|
|
Oct 12, 2008, 11:10 AM
|
|
OK, I was hoping is was not WAY over my head, but I think this is best to leave up to an expert. I have a guy coming out from a fireplace business to help me with just this scenario. Thought I would get a headstart and see if I could "do-it'myself". It's a lot more complicated than putting in a cabinet or something like that.
Thanks so much for the response
Nan
|
|
 |
Plumbing Expert
|
|
Oct 12, 2008, 01:28 PM
|
|
You will most likely be told that you need a millivolt compatible thermostat. Should still only need two wires. If you find a programmable thermostat that is millivolt compatible, it will be battery operated, so when the batteries die, the fireplace with shut off.
|
|
 |
New Member
|
|
Oct 12, 2008, 03:09 PM
|
|
Hey Dad77;
That is good and encouraging to know. I bought the 5-2 programmable Thermostat specifically because it states on the back that it is compatible with Gas Fireplace. But when I go to read the instruction for new or replacement instructions, it only refers to the 5 and 6 furnace labeled wires. I do not see any reference to it being millivolt compatible.
I just got the owners manual for my fireplace and it stated the electrical requirements is 120 volts.
WAIT... in here too... is
"SAFETY: AGA Certified Pilot Genator, Millivolt System activated with switch, remote control or Thermostat. "
I did not get the remote at the time of installation. Does this help?
|
|
 |
New Member
|
|
Oct 12, 2008, 03:10 PM
|
|
OH, I guess seeing that my fireplace is Millivolt does not answer if the thermostat is. I am not sure how to find it out other than call Honeywell. They are not opened today as I have already tried. :)
|
|
 |
Plumbing Expert
|
|
Oct 12, 2008, 03:42 PM
|
|
 Originally Posted by Naneegote
Hey Dad77;
That is good and encouraging to know. I bought the 5-2 programmable Thermostat specifically because it states on the back that it is compatable with Gas Fireplace. But when I go to read the instruction for new or replacement instructions, it only refers to the 5 and 6 furnace labeled wires. I do not see any reference to it being millivolt compatable.
I just got the owners manual for my fireplace and it stated the electrical requirements is 120 volts.
WAIT.... in here too... is
"SAFETY: AGA Certified Pilot Genator, Millivolt System activated with switch, remote control or Thermostat. "
I did not get the remote at the time of installation. Does this help?
This thermostat will work with your fireplace. All you need to do is hook the two wires from the (th-thp) on the gas valve of the fireplace to the (r-w) on the thermostat and you should be good to go. Please let me know if this helps, and good luck.
|
|
 |
New Member
|
|
Oct 12, 2008, 05:39 PM
|
|
It WORKS!!
I have been only able to test it about 2 feet away but the timer and the on/off switches work. I need to wire it externatlly around my basement, but it is OK. I can go along the top and hide it pretty well.
Can I use really long wire or is there a limit to the length that I should use. I want it on the other side of the room as the fireplace is on the end of long rectangular room.
I am so excited...
Thank you so much for your persistence to help me...
Nan
|
|
 |
Plumbing Expert
|
|
Oct 12, 2008, 05:59 PM
|
|
Glad to hear its working.
As far as the maximum length of wire goes, I can't say for sure. I would string out the amount of wire required to reach the spot you plan to mount the thermostat at and see if the thermostat works. If it does, then you should be fine. Since your thermostat is battery operated, you should be able to run a very long distance without problem. Hope you enjoy your fireplace(wish I had one)..
|
|
 |
New Member
|
|
Oct 12, 2008, 09:51 PM
|
|
Again, thanks.
I have enjoyed it for many years with just the on and off switch. I am having to rent out my basement and don't want a tenant to have to leave the heat on unnecessarily. So, I then remembered the I could get a thermostat for it. I heard that the remote thermostat costs about $180 and then I would have to get it from a dealer and that was about 6 years ago. I made an appointment to have him come out and talk options. His house call and the equipment, very expensive.
I started to think that I am a do-it-yourself kind of gal and so why couldn't I figure this one out. Went to Home Depot, spent $50 and was blessed enogh to find you and WaLa... I have a very cool working Programmable THERMOSTAT.
You're awesome.
Thanks so much.
|
|
 |
Plumbing Expert
|
|
Oct 13, 2008, 04:30 PM
|
|
You made the right move. I have found nothing but problems with remote thermostats.
|
|
 |
New Member
|
|
Nov 18, 2008, 04:06 PM
|
|
mygirlsdad77, my pilot stays lit, and when I turn thermostat on wall "on" my blue pilot flame runs along the burners right to left, but doesn't give me a full, real flame. So I'm not sure if my main burners are lit or not. Any ideas why I can't get fireplace to light up like last winter?
|
|
 |
Plumbing Expert
|
|
Nov 18, 2008, 04:17 PM
|
|
Please post this question on a new page. That way you will get more anwers from more experts. Sounds like your burners are lighting, but not getting full gas pressure. Do you know how to check gas pressures? Please do start your own post.
|
|
 |
New Member
|
|
Nov 18, 2008, 09:22 PM
|
|
Sorry, I did make a new post but nobody was answering so I put it here because I saw you were actively answering questions for people. No, I don't know how to test pressure. Plus, if it turns out it is low, which it probably is, which part would need replacing. The main gas is turned all the way up, so I don't know if something is only partially opening. I wish I knew my terminology better.
|
|
 |
Plumbing Expert
|
|
Nov 19, 2008, 04:39 PM
|
|
Are you on propane, or natural gas? You might not need to replace anything. You may be able to adust gas pressure. However, I would recommend calling in a pro. They will be able to locate the problem, and hopefully fix it at minimal cost. Sorry I can't advise you on how to check gas pressures if you are not familiar with it(to much liability).
Please let me know how this all turns out.
|
|
 |
New Member
|
|
Nov 19, 2008, 06:28 PM
|
|
Update, my friend (gas fitter) and I opened up the pipe which leads to the main burner to find a spider web clogging inside at basically 99%. Which would explain why but burner did light but stayed a small blue flame. So we gave everything a good cleaing and voilą! So thanks again for all your help. All is good!
|
|
 |
Plumbing Expert
|
|
Nov 20, 2008, 05:32 PM
|
|
Damn spiders. Just glad you got it fixed. Sounds like you owe your friend a case of beer, Or (if he is like me) a bottle of whiskey. Take care.
|
|
 |
New Member
|
|
Jan 1, 2013, 09:15 AM
|
|
Do these instructions work with a wireless thermostat?
|
|
 |
New Member
|
|
Nov 18, 2015, 09:27 PM
|
|
THANKS MYGIRLSDAD!! I bought an Emerson Sensi Wifi thermostat and connecting it as you suggested to my millivolt fireplace worked! I couldn't find any useful information anywhere telling me how to hook it up. Thanks a bunch!!
|
|
Question Tools |
Search this Question |
|
|
Add your answer here.
Check out some similar questions!
Installing programmable Thermostat
[ 2 Answers ]
I am upgrading my old cheap mercury thermostat with a Honeywell programmable model - RTH6300B (a 5-2). When I removed the old unit there were two wires - black & white (labelled B and W). The new unit has 6 connections - C,G,W,Y,R & Rc. There are a number of alternate letters given:
C - X or...
Installing programmable thermostat?
[ 4 Answers ]
I just purchase a new Honeywell RTH4300B programmable thermostat for my oil furnace. My old thermostat was a White-Rodgers and was connected with 2 wires; one red and one black. There was no coding on the terminals and everywhere I look they are always talking about a red and a whir wire. I think I...
Installing a programmable thermostat
[ 1 Answers ]
Im having a problem installing my new programmable thermostat. The connected wires on the old mercury one are Y, Rc, W, B, G. The ones on the new one are G, Rc, Rh, Y/O, W/B, Y1 and I can't figure out where to put them off the diagram that they sent in the package.
Installing a Programmable Thermostat
[ 1 Answers ]
I have a 10 year old Carrier thermostat and want to install a new programmable thermostat.
The thermostat has 5 wires (red, yellow, green, blue and white). All of the programmable thermostats only instruct you on how to install with 3 or 4 wires.
Does anyone have a suggestion on a...
View more questions
Search
|