    Installing new Honeywell rth2300 thermostat
    I just replaced an old digital thermostat with a new programmable honeywell. The wires coming out of the wall are as follows:
    Red
    White
    Blue
    Green

    In the old thermostat they were connected as follows:
    Red:Rh (jumpered to RC)
    White:W
    Blue:Y
    Green:G

    The unit is a gas heater/AC unit. I called honeywell about this but just want to double check. The new honeywell unit does not have an RH or RC terminal, just an R. Honeywell told me that I don't have to jumper in this new unit because just plugging the red wire into the R terminal will take care of it. They said it would only be problematic if I had separate wires coming into the house to the RH and RC terminals. The heat is running fine right now so I feel they are correct. Do I need to just put the old unit back up or are they correct?
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Jan 5, 2010, 10:10 AM
    Do I need to just put the old unit back up or are they correct?

    If the new thermostat is functioning properly I see no problem. You do not have separate R terminals to worry about so stop worrying.
    aadepa's Avatar
    aadepa Posts: 2, Reputation: 1
    New Member
     
    #3

    Jan 5, 2010, 11:06 AM

    Great. Thanks. My concern I guess is whether it will affect the AC when we run it. I would test it but since it is below zero out the manual recommends against that.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

W o g are c why wires thermostat = rth2300 [ 3 Answers ]

My old thermostat has the wogrcy and when I connect the new model rth300, the ac doen't run

Diagram for honeywell RTH2300 wiring module [ 3 Answers ]

I am trying to connect the wire to the themostat but the wire has 1 thick copper wire and doesn't have many wire colors to hook up to themostats. Our landlord left without finishing the set up on our wall heater(gas) and expected us to do it ourseleves. I am having trouble finding a module diagram...

Installing Honeywell Thermostat [ 13 Answers ]

I'm installing new thermostat - all wires/lettering corresponds from old to new with the exception of new one has a slot for "w"but I have two wires left "w1" and "w2". "W1" is tan and "w2" is yellow. Thanks for the help!

Installing a Honeywell programmable thermostat [ 1 Answers ]

I am replacing an old mercury thermostat with a honeywell rth7000. I have a heat pump Unit. Current Mercury wired as such: Red wire to R Brown wire to T Orange wire to O Green wire to G Yellow wire to Y Blue wire to B

Installing RTH7400 Honeywell Thermostat [ 1 Answers ]

I am replacing my (old) Honeywell T8411R thermostat with a (new)Honeywell RTH7400 programmable thermostat. I need help wiring to the new thermostat. My H/C system is a heat pump system. The old thermostat is wired to the following terminals: W1 - White W2 - Brown G - Green R - Red C - Blue...


View more questions Search