Ask Experts Questions for FREE Help !
Ask
    FreddyH's Avatar
    FreddyH Posts: 2, Reputation: 1
    New Member
     
    #1

    Aug 31, 2008, 10:31 AM
    HVAC Trane xv80 blower motor
    Trane XV80 Installed 2002
    My blower does not come on; I turned t-stat to fan only; fan motor felt cold to touch and turns freely when spyn: defeateded the safety switch on front; checked voltage at the leads from the circuit board to fan motor for the white and black leads(124 v);
    Should I connect a power cord directly to fan motor to test?
    letmetellu's Avatar
    letmetellu Posts: 3,151, Reputation: 317
    Ultra Member
     
    #2

    Aug 31, 2008, 12:27 PM
    When you have the front off the furnace and depress the safety switch do you hear a click? If not you could have a bad transformer.

    Have you checked anything except the fan on switch, have you tried setting the thermostat on heat to see if it works. Also there is a test terminal you can use to make the furnace go through a cycle to make sure all systems work, except the gas. Read on the bottom door for instructions.
    FreddyH's Avatar
    FreddyH Posts: 2, Reputation: 1
    New Member
     
    #3

    Aug 31, 2008, 01:11 PM
    Yes I hear a click;
    The red light continues to flicker and a yellow light at the bottom of circuit board comes on.
    I did set the t-stat on heat, increased the temp to 85 to get the heat to come on; no fan motor. Hopefully that cycle test will indicate problem
    I run that test; thanks

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Trane XE80 Blower Motor Kaput [ 2 Answers ]

Had an AC salesman out today about replacing the upstairs unit. He was demonstrating "proper air flow" with the basement unit. He opened the furnace and the blower motor made a squealing noise when it came back on. He flicked the power off and then on again and the noise disappeared. He said it...

Trane XV80 blower not running [ 2 Answers ]

:( I have a Trane XV80 blower motor will not run, it will spin freely, the control board has normal slow blink, but GS3 yellow LED light above green wire is on, when A/C turned on the condensing unit runs but no blower, Heat on no blower but get trouble light high limit lockout, and just turn...

Trane xv80 [ 1 Answers ]

Main blower mysteriously stopped working on Trand XV80. I've gone through the owner's manual. No fix. Vent blower works, flames present, no main blower. 16 Months old. Any suggestions?

HVAC blower motor--screwed up wiring-- HELP [ 11 Answers ]

Relaced blower motor, but wires are different from old motor--can hear it click on, but nothing else. Have part and model numbers for old motor (GE), new motor (Dayton-PSC), and HVAC (Goodman) Please Help-- am burning up here--(south texas)

Squeaky Trane Blower Motor [ 1 Answers ]

Noticed last night that my Trane furnace was squeaking like a cricket when the air conditioner was running. Then every so often it would make an awful squealing sound like maybe a motor was getting stuck and unable to turn. From reading other posts I'm guessing that I might have a bearing or belt...