    How-to test furnace relay
    Unit: "Old" Sears Furnace Age: Unknown; Model#: 867.763271; A/C: Kenmore condenser/cooling coil are newer add-ons probably mid-90's; Blower Fan: Emerson 1/3 hp direct drive, looks-like updated model.

    Problem: Recently, the blower fan on our furnace stopped running and yet the condenser continued to run. While inspecting the blower fan, I found a manual circulation switch on the bottom of the Electrical Comfort Center inside the furnace and switched it on and the blower fan started. I suspect the double pole double throw Plug-In Relay, but not sure how-to test it to verify. Any other suggestions would be greatly appreciated. Thanks.
    wmproop's Avatar
    wmproop Posts: 3,749, Reputation: 91
    Ultra Member
     
    #2

    Jul 21, 2010, 08:53 AM

    With tstat calling for fan on with meter check for power coming out of relay going to motor,make sure you no there is power going into relay and coming out
    Stratmando's Avatar
    Stratmando Posts: 11,188, Reputation: 508
    Uber Member
     
    #3

    Jul 21, 2010, 08:57 AM

    Also check for the 24 volts at relay coil.
    With 24 volts present and 240 volt power at input of relay, you should get power out of relay(240 volts)

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Relay switch for furnace [ 1 Answers ]

Have electric furnace with heat pump. Replaced thermostat and now the emergency heat will not work. Thought I might have hooked up wrong so I called maker of thermostat and talked with them. They said the wiring was correct. The heat pump works and the blower comes on when emergency heat is on but...

93 Honda Civic DX. Comp.K-Test, main relay,fuses,rang all wires. 0VDC fuse 18. [ 1 Answers ]

I have a 1993 Honda Civic DX. I have done K-Test, replaced main relay, checked all fuses, and rang out all associatred wires. I get 0V at fuse 18. Where does fuse 18 get its power from. My drawings are crap. Where can I get some good, complete electrical drawings?

91 honda civic main relay and continuity test [ 1 Answers ]

In my 1991 honda civic Rocky my husband wants to know : he say's while testing main relay from term 2 and ground he found no ground . So he hooked up a ground and there is continuity now Now on the pgm dash fi1 main relay program fuel inject check for voltage term #6 We have no term #6 his...

Furnace relay switch [ 13 Answers ]

After duct cleaning my furnace (heat and air) does not work anymore. The thermostat indicates the system is on. Furnace light is on but the fan is not turning. There is that switch that you press when you open the door to the furnace. I guess is a relay swtich. On when door is closed and off when...

Faulty Relay in Furnace [ 2 Answers ]

Hi everyone. My Concord two zone oil fired forced hot air furnace decided to stop coming on the other day. It has a Honeywell EMM-3 zone controller, a relay and a transformer. I had my oil dealer come and look at it, it was working for him. After he left, it stopped again. I took matters into my...


View more questions Search