    How much loss would I have if I install a 3ton cooling unit in a GMP150? (aprox)
    I have a GMP150 gas heating unit working at home. I now want to add the cooling unit, but due to the small size of the house (about 70m2) I want nothing more than 3 ton unit. Given this requirement, all local Goodman people I contacted told me that I have to install the 5 ton unit because the 3 ton unit will give 'no cool at all' in the house. I understand the air speed using GMP150 can be faster than expected by the 3 ton unit, so, I may expect some loss in its cooling capacity. However, is hard to me to believe that such loss would be of 100% ('no cool at all'). The question is: Can you give me an estimate of the loss of coolig capacity if I install a 3 ton unit (e.g. Designed for GMP100) on top of my GMP150?
    wmproop's Avatar
    wmproop Posts: 3,749, Reputation: 91
    Ultra Member
     
    #2

    Feb 1, 2012, 03:46 PM
    It would help me, maybe someone else knows,, but I`m in USA,, we measure homes in square feet, so unless someone comes along maybe you can convert 70m2 to something I can understand
    mygirlsdad77's Avatar
    mygirlsdad77 Posts: 5,713, Reputation: 339
    Plumbing Expert
     
    #3

    Feb 1, 2012, 04:17 PM
    I think what they are trying to tell you is you need to match the outside unit to the indoor coil, the furnace shouldn't make any difference. You can adjust fan speeds to allow for different applications. If you have a 5ton coil on top of the furnace, you need to match it with a five ton unit outside. Either that, or take out the coil and install a three ton coil and condenser. Then adjust airspeed in furnace accordingly through testing. If the house is small, why such a large furnace? If the house is big, go with the five ton as suggested by installer. If they did a manual J on the home, they most likely sized everything correctly. Why are you not agreeing with them? Or maybe you need to call in a different company and have them tell you what they think, heck even two or three more companys and get their advice.

    I will tell you that if you undersize your a/c, you will regret forever. However, if you extremely oversize it, you won't be happy either. Im still trying to figure out why you have such a large BTU furnace, but say the house is small? Confused. Can you clear this up for me?
    wmproop's Avatar
    wmproop Posts: 3,749, Reputation: 91
    Ultra Member
     
    #4

    Feb 1, 2012, 04:24 PM
    mygirlsdad77,, now I`ll never find out what 7m2 means
    pablodg's Avatar
    pablodg Posts: 2, Reputation: 1
    New Member
     
    #5

    Feb 1, 2012, 04:50 PM
    Hi, 70m2 are 753 square feet. The furnace is so bit because the house was going to be bigger, but it won't.
    mygirlsdad77's Avatar
    mygirlsdad77 Posts: 5,713, Reputation: 339
    Plumbing Expert
     
    #6

    Feb 1, 2012, 05:08 PM
    Okay, so you had the sizing of the furnace done for future addition, which you have now decided not to do, correct? For that footage, even three ton seems oversized. Just make sure to match the evap coil and the condenser, and have it properly sized for the home. The only real problem I see is if the evap coil is to small and will restrict the airflow of the furnace, but most newer coils of any BTU are large enough to make your system work correctly. Leave this one up to the pros you have in your area. I hope our furnace is a two stage furnace, or you may find that is will cause problems due to the extreme oversize. I think you would have been fine with a 90,000 BTU furnace, and that may even be a bit oversized. Good luck on your project, and please do let us know how things work out.
    mygirlsdad77's Avatar
    mygirlsdad77 Posts: 5,713, Reputation: 339
    Plumbing Expert
     
    #7

    Feb 1, 2012, 05:12 PM
    wmproop, looks like we both learned something today,, but I'm betting we will never have to remember it? 70m2, is that metric? How would you calculate that to square feet?
    wmproop's Avatar
    wmproop Posts: 3,749, Reputation: 91
    Ultra Member
     
    #8

    Feb 1, 2012, 07:33 PM
    As advised before,, someone should do a manuel J calculation on your house,, as you know the furnace is to big, but also I`m guessing a 3 ton air is also to big,, that size house 2 ton at the most

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Central a/c unit -not cooling service man filled it with feon but still not cooling [ 7 Answers ]

I have a kenmore 3 ton 14 series unit. At night it cools good but day time it goes to 80 degrees. The compressor had a leak so the service man filled it up. Wasn't the service man suppose to change the dryer on it? The hose outside is not even cold and in the house it blows a little cool air but...

Is it right to replace a 10 seer 3ton condensing unit (r-22) with a 13 seer 3ton [ 4 Answers ]

Will it be OK to replace a 10 seer 3 ton condensing unit (r-22) with a 13 seer 3 ton (r-22) without any changes to the 10 seer air handler(indoor unit)? I would appreciate your fieldback! Thanks, Gray

Trane XL1800 3ton condensing unit [ 9 Answers ]

I've mated a 1991 Rheem Ahu with a 2001 Trane XL1800 Condensing Unit. He condensing unit is dual stage compressors and I have the high side wired to call. I know need to upgrade the ahu and the honeywell chronotherm III t-stat but budget is not allowing it yet. I had a new coil installed with a...

Wiring a goodman 3ton a/c unit [ 4 Answers ]

I have installed a goodman 3 ton a/c unit and was told I need to install two 30 amp breakers one for heat and one for the a/c. do I run one leg to a/c and one to the heat strips. Thanks

Goodman 3ton split unit Heat will not come on [ 10 Answers ]

After turning up heat, blower will not come on, or the heat. What do I look for or trouble shoot?. thanks


View more questions Search