    How do I check my control board. I replace the hot surface ignitor there times
    I I'm a hvac tech for an apt complex. But this problem is at home. I have worked on gas units this is given me a go my led tells me flame sensor.. I replace it... it ran then went out again.. how do I check the board?? Is there a amp reading for the wires from the board to the ignitor it will not glow.. this is a kenmore goodmen product... gmp075-3
    bitters's Avatar
    bitters Posts: 348, Reputation: 12
    Full Member
     
    #2

    Nov 20, 2014, 10:26 AM
    A little confused, you replace the igniter three times and the flame sensor? OHM out the igniter and see what you get.
    Grady White's Avatar
    Grady White Posts: 1,417, Reputation: 59
    Ultra Member
     
    #3

    Nov 20, 2014, 07:38 PM
    Measure voltage at the ignitor terminals on the board. If you get 120 volts shortly after the venter comes on & the ignitor does not glow, ignitor is bad.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Inducer blower and hot surface ignitor not coming on [ 0 Answers ]

I have a ruud furnace I just put a blower motor in and I put all the wires back as on the diagram on my furnace but the ignitor or inducer blower is not working now what can be the problem

Blower working,hot surface ignitor not lighting up [ 24 Answers ]

My furnace is a Carrier,about 9 years old. My blower runs but there is no heat. Have done some research so I replaced the HSI because there was a white spot on it and it was not lighting up. It still is not lighting up. Could someone tell me what I should do next. Thanks.

Avg cost of furn/diaog and replace hot surface ignitor [ 2 Answers ]

Could someone tell me the average or ball park cost of having a furnace diagnosis and a hot surface ignitor replaced. Thank you

Comfortmaker Furnace Hot Surface Ignitor Failure [ 2 Answers ]

I have an 1989 vintage Comfortmaker furnace. Over the past couple of years, the burner goes out shortly after it starts up. When I replace the hot surface ignitor, it starts working again normally. I have had to replace the ignitor lately every one to three months. I have had a technician look...

Hot surface ignitor [ 1 Answers ]

What would cause a hot surface ignitor to explode?


View more questions Search