    Phil196's Avatar
    Phil196 Posts: 2, Reputation: 1
    New Member
     
    #1

    Mar 5, 2007, 08:36 AM
    Hot water continuously runs into expansion tank
    I have an indirect water heating system and the hot water from the tank is running into the central heating expansion tank, it does not fill up and go down the overflow so I caan only assume that the central heating water is leaking into the hot water tank and going out of the overflow into the expansion tank and the expansion tank is compensating for the loss of central heating water. 1. Am I right in assuming this to be the problem and 2. is it fixable or do I have to buy a new tankl 3. Do I just leave it ?
    doug238's Avatar
    doug238 Posts: 1,560, Reputation: 62
    Ultra Member
     
    #2

    Mar 5, 2007, 08:21 PM
    Are you getting your heat from underground?
    Phil196's Avatar
    Phil196 Posts: 2, Reputation: 1
    New Member
     
    #3

    Mar 12, 2007, 04:09 AM
    Sorry doug, been away, My hot water is heated by an oil fired boiler with a circulating pump for the central heating, the same boiler heats my hot water by circulating the central heating water through a coil in the hot water tank (HWT) and so heats it up. The HWT has an overflow (I suppose in case the water boils?) which feeds into the central heating system expansion tank and then overflows outside if it overfills. When my central heating is switched on there is a constant trickle of water into the expansion tank, the level of water in the expansion tank never increases so the flow into the expansion tank must equal the water loss from the central heating system. I'm pretty confident that the coil within the HWT is leaking, just want to know if it is repairable?
    doug238's Avatar
    doug238 Posts: 1,560, Reputation: 62
    Ultra Member
     
    #4

    Mar 13, 2007, 09:03 PM
    I would think it is too costly to repair.
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #5

    Mar 14, 2007, 12:56 AM
    Disconnect lines and pressure check to be sure.
    labman's Avatar
    labman Posts: 10,580, Reputation: 551
    Uber Member
     
    #6

    Mar 14, 2007, 09:48 AM
    If water from your heating system is leaking into your domestic hot water, it could be back feeding into your potable water. You need to get it fixed now. How much? That depends on how old the system is, can you buy any parts you need, and how easy it is to remove and repair/replace the coil. If you are not comfortable with removing the coil yourself, better have a HVAC professional look at it.
    NorthernHeat's Avatar
    NorthernHeat Posts: 1,455, Reputation: 132
    Ultra Member
     
    #7

    Mar 14, 2007, 03:02 PM
    Just cap off the lines that went to the domestic water tank and install a conventional water heater, should cost approx' the same to operate and allot less to install.

    I think however, something is wrong with your understanding of the system, the expansion tank for for boiler should be about 15 psi and the pop-off is rated at 30. I think you are calling the overflow the pop off. If this is a low pressure steam boiler, it may truly have an overflow, so the boiler doesn't flood, but since you said you have a circulating pump that can't be.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Water heater expansion tank [ 2 Answers ]

I have a four year old water heater that is leaking out the pressure release down tube and there is an expansion tank fixed to the cold side. I tested the pressure on the expansion tank and it reads 0.00. Is there supposed to be some amount of pressure reading in the expansion tank or can I add...

Water Heater Expansion Tank [ 1 Answers ]

It's me again. I meant an under the air conditioner hot water heater. The current one is 31" high. It has an expansion tank, but I was told it wasn't necessary. I'm in a second floor condo. Is it really necessary and if so, why? Thanks a lot.

Water heater expansion tank [ 2 Answers ]

I need a new water heater and one plumber says the expansion tank on the side is not necessary. Is it? What is the average cost of a 40 gal, under air water heater already hard wired? 2nd floor. Thanks

Water heater expansion tank [ 4 Answers ]

Read a post here concerning the water line back flow preventer/expansion tank and am familiar with its operation and purpose when using city water. My question is, is this setup recommended or even needed on a well water system? My feeling is that the holding tank would take up any expansion. ...

Outside fan runs continuously [ 5 Answers ]

This is a very helpful sight and I am hoping someone can give me some advice. I have a fairly new house (5 years old) and I am having some problems with a Carrier unit. At the end of this summer it started tripping the breaker on very hot days and we called a technician whom found nothing wrong. ...


View more questions Search