    richard44's Avatar
    richard44 Posts: 1, Reputation: 1
    New Member
     
    #1

    Oct 16, 2006, 12:09 PM
    Heil gas furnace won't blow
    I have a Heil heat/air gas pack(forced air) unit. It's about 20 years old, but it's been a great one. When I flip the t-stat to HEAT and AUTO I hear the unit outside firing up and I can see heat rising out of the vent, but the blower won't come on to push heat inside my house. When I turn the t-stat onto FAN(and the other switch onto HEAT), everything works fine, and heat is blown into house. Can't be the blower because it works on FAN. What do you think?
    labman's Avatar
    labman Posts: 10,580, Reputation: 551
    Uber Member
     
    #2

    Oct 16, 2006, 12:29 PM
    Often blowers have a higher speed for cooling and fan on. They use a different relay or limit switch to energize a different winding for a slower speed for heat. So check to see if the limit switch is closing shortly after the gas comes on. Also check to see if any relay for the blower is working. With an older system you may have a separate component easy to trouble shoot and cheap to replace. Newer systems have everything on a control board. $$$$
    NorthernHeat's Avatar
    NorthernHeat Posts: 1,455, Reputation: 132
    Ultra Member
     
    #3

    Oct 16, 2006, 01:57 PM
    You got to decide what controls the heat blower speed it could be a fan limit control, or a PC board. 20 years old huh, the last time it was serviced? Fer safety sake people if you don't know how to inspect a heat exchanger, call a pro. You have know idea how many Americans get CO poisoning each year, and a day in a hyperbolic chamber is very expensive, if your that lucky.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Gas furnace [ 2 Answers ]

For the past 2 nights my furnace has been blowing out cold air. I have a furnace which is equipped with an ignition device which automatically lights the piolet. I did everything from cutting off the gas valve and power to furnace. When I restarted everything back up, the furnace came on but no air...

Can't get furnace to blow hot/cold air! [ 4 Answers ]

:confused: I recently moved into a house & I can barely tell that any air is coming out. I have just paid to have all the ducts cleaned. Please help me figure this out.

Gas Furnace Doesn't Lite [ 3 Answers ]

My Carrier Furnace Igniter glows but the valve won't turn the gas on. I have discovered that the relay switch on the top of the valve has a bad connection to the pins (2 each) on the two solenoids. I can loosen this and slide up and down several times and it will work for awhile. My problem is that...

Gas furnace [ 14 Answers ]

Igot a 1972 carrer furnace it catches fire at the spud part of burner I got 11.5 inch watter column preasure on line you can cut it off turn it back on and it burns good blaze looks good I need some comet on air ajustment or what might be causing this I have cleaned the burners , thanks.

Heil 92% H9MPDO75F12B Gas Furnace [ 1 Answers ]

I had a Heil Gas Furnace installed and from the first day I notice that when the blower came on the air was on the cool side. After about 1 to 2 minutes the air became a little bit warmer but never got hot. My question is this normal or do I have a problem? Please let me know as soon as possible so...