Ask Experts Questions for FREE Help !
Ask
    pumpman's Avatar
    pumpman Posts: 1, Reputation: 1
    New Member
     
    #1

    Jan 20, 2007, 11:42 AM
    Heil furnace short cycling of burner
    My 1983 heil model NUGK075DG01, natural gas, forced air furnace is running but only heats the house to 67 degrees no matter how high I set the temp, the fan continuously runs (in auto on thermostat) and the burner will cycle for 3-4 min. then shut-off for 10 min..
    I have powered down and back-on, no change in operation. It is currently 6 degrees outside and my family is tired of being cold, any help would be greatly appreciated.
    rickdb1's Avatar
    rickdb1 Posts: 185, Reputation: 15
    Junior Member
     
    #2

    Jan 20, 2007, 07:44 PM
    The flame may be going out on limit (Dirty filter, Clogged "A" coil, Dirty blower wheel, Etc.) or it's possible that the flame sensor or thermocouple may need replacing because it may be telling the furnace to shut down because a flame is not detected. It could also be low gas pressure going to the furnace. I'm leaning toward it's going out on high limit... Check the filter first, then have someone come out and have a look..

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Well motor -Short Cycling [ 13 Answers ]

Old houses... great aren't they? I have a new dilema. Seems as though the well motor is beginning to short cycle during a shower or if the washer is running. I would suspect the pressure switch, however I do not know which side is the low side and which is the high side, nor do I know where to...

HEIL furnace will not stay lite [ 3 Answers ]

I have a older heil furnace (Model#867.769445) about 20 years old. When the pilot turns on after a few seconds the burners light, then after a second or two they shut off, on again, and off. They will do this continually until finally they stay on or the furnace stops trying to heat. I have also...

Heil gas furnace won't blow [ 2 Answers ]

I have a Heil heat/air gas pack(forced air) unit. It's about 20 years old, but it's been a great one. When I flip the t-stat to HEAT and AUTO I hear the unit outside firing up and I can see heat rising out of the vent, but the blower won't come on to push heat inside my house. When I turn the...

Heil 92% H9MPDO75F12B Gas Furnace [ 1 Answers ]

I had a Heil Gas Furnace installed and from the first day I notice that when the blower came on the air was on the cool side. After about 1 to 2 minutes the air became a little bit warmer but never got hot. My question is this normal or do I have a problem? Please let me know as soon as possible so...

Oil burner Blower cycling on and off [ 2 Answers ]

Just finished with a new second floor addition. Upgraded to two zone heating from single zone. When heat comes on after expected delay for temp to rise the blower comes on for fifteen seconds then kicks off and comes on again in about two or three minutes, and kicks off again in fifteen seconds, on...


View more questions Search