    preeves's Avatar
    preeves Posts: 1, Reputation: 1
    New Member
     
    #1

    Oct 16, 2010, 03:30 PM
    Heat pump runs in a/c mode but won't come on in heat mode
    I am selling my house and the home inspector noticed that when you turn the heat on, the heat pump doesn't come on and goes to auxiliary heat. It works fine for air conditioning and when I call for heat at the stat and push the contactor in manually it is blowing cold air out of the condensing unit. Also when I first turn the heat on at the stat I can briefly hear the contactor trying to pull in.
    elephantears's Avatar
    elephantears Posts: 30, Reputation: 3
    Junior Member
     
    #2

    Oct 19, 2010, 07:47 PM
    You have a situation that needs to be addressed by a professional. It sounds like you have done all that you can. I will give you a link to a site that simplifies the operation of heat pumps if you are handy with an electrical meter, you could prove that the thermostat is bad or that a rat has chewed the thermostat wires.
    The person that finds and fixes your problem will have earned his pay.
    www.theheatpumpmadeeasy.com
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #3

    Oct 19, 2010, 11:34 PM
    Quote Originally Posted by preeves View Post
    I am selling my house and the home inspector noticed that when you turn the heat on, the heat pump doesn't come on and goes to auxilliary heat. It works fine for air conditioning and when i call for heat at the stat and push the contactor in manually it is blowing cold air out of the condensing unit. also when i first turn the heat on at the stat i can briefly hear the contactor trying to pull in.
    Usually the coil on the reversing valve or the reversing valve itself is defective. Testing the coil is easy but if it is the valve itself the work will have to be done by a professional since it involves removing the refrigerant from the unit and brazing in a new valve. Then the unit will have to be recharged.. You can also check to see if 24 volts is going to the reversing valve when calling for heat. Good luck.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Installed a honeywell pro6000 stat on a carrier heat pump, cooling mode is heat pump [ 2 Answers ]

Installed a honeywell pro6000 stat on a carrier heat pump, cooling mode is heat pump

Trane heat pump defrost mode won't finish working stops after 3 minutes [ 1 Answers ]

Trane heat pump won't defrost automatically when I try it manually it comes on but only staying on for about 3 minutes and never gets to defrost

Blower motor won't shut off in heat mode but works fine in A/C mode [ 0 Answers ]

I have an older lennox unit that is pilot light. The blower motor won't shut off when the temp is reached on the thermostat but it works fine in ac mode. What could cause this? I'm confused because it worked 2 weeks ago when I turned my ac off and the thermostat is in auto and only shuts off when I...

Carrier heat pump works fine so far, won't go into defrost mode [ 1 Answers ]

I have a carrie heat pump that is working fine so far. It still provide heat for my home. It just dose not go in to defrost mode to defrost the out side unit. I have read to put the unit in auxialry mode to get a few extra defrost cycles in, but when I read the flash codes it never say anything...

Fan runs forever when in heat mode but not in ac mode [ 2 Answers ]

Great web site and concept!! I have a York forced air gas furnace that has a Honeywell Fan Limit switch. The unit works great in the summer. The ac and the fan shut off correctly. However, in the winter the heat will reach its temp setting and turn off but the blower continues forever. I have...


View more questions Search