    I have a fan from an old Carrier heat pump and was wondering if I am able to wire it to beable to use it as a fan in my garage. The 3 wires coming from the motor are brown, white and black? If able, how would I wire it?
    hkstroud's Avatar
    hkstroud Posts: 11,929, Reputation: 899
    Home Improvement & Construction Expert
     
    #2

    Jul 24, 2011, 09:33 AM

    Fan is probably a 240V and probably requires capacitor.
    ma0641's Avatar
    ma0641 Posts: 15,675, Reputation: 1012
    Uber Member
     
    #3

    Jul 24, 2011, 09:50 AM
    Look at the fan and see if it is 120VAC. If so, you should be able to use the black and white. Make up a test lead from an old cordset, connect the wires and plug it in. Make sure the fan is anchored well. If it runs fine. If it trips the breaker, you may try brown and white. Look for a wiring diagram on the fan.
    DIY13700's Avatar
    DIY13700 Posts: 6, Reputation: 1
    New Member
     
    #4

    Jul 24, 2011, 09:51 AM
    Thank you. I thought that may be the case.
    DIY13700's Avatar
    DIY13700 Posts: 6, Reputation: 1
    New Member
     
    #5

    Jul 24, 2011, 11:14 AM
    I was mistaken - the white wire is actually yellow. I did see there was a diagram on the motor, blk being common and the other 2 connected to the capacitor. The plate had CAP 7.50/350. Is this the type of capicitor I need? If not, I assume I can look find the size needed by looking up the motor number on the net?
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #6

    Jul 24, 2011, 11:15 AM
    Almost all HVAC fans need a run capacitor no matter weather it is 115 volt or 220 volt. The person who mentioned the wiring diagram is correct look on the fan MOTOR or on the old furnace/a/c unit for a wiring diagram. If you try to run the motor without the proper value run capacitor you will destroy the motor. Good luck with keeping cool.
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #7

    Jul 24, 2011, 11:18 AM
    Comment on DIY13700's post
    You are correct (7.5 MFD / 350 volts) is what you need. Wire as per the diagram on motor.
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #8

    Jul 24, 2011, 11:19 AM
    Comment on DIY13700's post
    You are correct (7.5 MFD / 350 volts) is what you need. Wire as per the diagram on motor.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Carrier Heat Pump we turned it to heat, inside fan runs outside fan doesn't [ 1 Answers ]

We changed our heat pump from AC to heat, noticed the inside fan ran all night. Checked in the morning and the outside fan wasn't running. Turned it off and back on there is a click but the fan doesn't start. Turned the setting back to AC to see if it would run acts the same as with heat, exterior...

Heat won't shut off on heat pump and outside fan not running [ 2 Answers ]

My heat pump runs continually inside in heat mode but the fan motor outside won't run. If I make it cooler in the house (65 or so) it will run properly. If the a/c is on and I lower it to 70 inside the outside motor won't work again but the compressor unit runs. Have already replaced fan motor...

Heat pump fan has been running for an hour, the heat is not on or ac is this normal? [ 3 Answers ]

My electrical heat pump fan has been running for an hour or two the heat is not on or the ac is this normal?

Goodman cpl t30-1a heat pump, heat not working/no compressor or fan operation [ 5 Answers ]

The thermostat is operating/clicks on when desired temperature is more that the actual, but no action at the compressor or fan. We even switch thermostats from other unit in house and both operate the other unit correctly.

20 yr old Lennox heat pump fan blows constantly in heat mode [ 5 Answers ]

20 year old Lennox heat pump - outside temps been 30's at night, 40's daytime UPDATE: I went outside and the unit is covered in frost on 3 sides! I've been reading on Google about frosted heat pump units and can't determine how to manually defrost it. Apparently, the auto defrost is not...


View more questions Search