Ask Experts Questions for FREE Help !
Ask
    Rahunn's Avatar
    Rahunn Posts: 2, Reputation: 1
    New Member
     
    #1

    Sep 30, 2012, 09:23 PM
    I have a York Diamond 80 furance and how can I tell if it was changed to use propane
    I have a York Diamond 80 furance and how can I tell if it was changed to use propane.
    ma0641's Avatar
    ma0641 Posts: 15,675, Reputation: 1012
    Uber Member
     
    #2

    Oct 2, 2012, 06:58 AM
    May or may not be easy. Check the gas valve, it should tell you if it is NG or propane. If not, remove the pressure regulator cap and see if the small diaphram rod is marked NG OR LPG. If all else fails get the BTU rating, take a jet to the LPG distributor and have them measure it.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

York diamond 80? [ 0 Answers ]

York diamond 80 main burner ignites & goes out 7 red flashes after

York Diamond 80 [ 1 Answers ]

I have a York Diamond 80 and blow motor continues to run even when the thermostat is in a off position. When you turn the thermostat to the on poisition and set to temp for heat the blower will turn off and the heat will kick in and will run fine. Once the house reaches it's temp. The heat will...

York Furance only blowing cold air [ 1 Answers ]

We installed a new thermosat for our electric furnace "york" about 25 years old. When we started it to heat the house it only blew cold air; looked at wiring tired it again still coldair. Put the old thermosat back on and the furnace is only blowing "cold air". Is it possible we "blew"something...

York Diamond 90 [ 1 Answers ]

I have a york diamond 90 and I have 4 code show what could it be