Ask Experts Questions for FREE Help !
Ask
    coccaro54's Avatar
    coccaro54 Posts: 1, Reputation: 1
    New Member
     
    #1

    Jul 25, 2010, 08:07 AM
    I have a Trane air handler 1996 model and the fan won't turn off.
    My trane air handler fan won't turn off. The condensing unit will turn on and off with the stat. I made sure the fan switch was in auto. I disconnected the green wire and it still ran, Thanks
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Jul 25, 2010, 08:23 AM

    Bad relay on the circuit board if so equipped. Test board if possible if not replace. If standard fan relay just replace relay.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Trane Air Handler won't come one [ 15 Answers ]

Hello, My air is not working. The thermostat is set to 77 degrees and it is 80 degrees in the house. I have turned the breaker off and back on. The fan on the unit outside the house is running, but cool air is coming out, not warm as I expected. I turned everything off for 2 hours to see...

My air handler fan does not turn on [ 5 Answers ]

In A/C mode, the comppressor turns on , but the fan will not. In heat mode, nothing happens, I'm thinking because the fan needs to run to withdraw the exhaust from the gas. If I turn the fan switch to "on" still have no fan. I have a digital thermostat Any help out there. Thanks in advanced.

What air handler with Trane XR-13? [ 3 Answers ]

Last year I had a new 5 ton Trane XR-13 external unit installed but did not replace the air handler inside. I want to do that now since it is 15 years old and has had mechanical problems lately. A variable-speed air handler would cost about $800 more than a non-variable but seems like a good deal...

Central Air, Handler Fan will not turn without a helping push [ 6 Answers ]

I have a Lennox, 10 year old central air unit in my condo. The Air Handler Fan is not turning on as it's supposed to. I opened the unit and gave the fan a spin, and then it worked fine but still will not start on its own. I put the fan on manual and just letting it run, and that's keeping the...

Trane Air Handler [ 1 Answers ]

We recently purchased a Trane 16Xi with a Trane 4TEE variable speed air handler. The air handler has been installed upside down. Is this right? At 75 degrees the compressor is coming on for 10 minutes. shutting down for 20 minutes. The humidity in the house is running 57% to 61%. Outside...