Ask Experts Questions for FREE Help !
Ask
    Oppy38's Avatar
    Oppy38 Posts: 1, Reputation: 1
    New Member
     
    #1

    Jan 10, 2010, 09:35 PM
    I have a gas fired hot water boiler. There is water coming out of the release pipe.
    The pressure seems fine on the boiler, but water comes out of the pressure release pipe. I have no idea when this happens, but it does not happen continually. How can I stop this from happening? I drained the tank, but this did not help.
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Jan 11, 2010, 12:59 AM
    The pressure relief valve releases water when

    The system has to much water pressure in it. This is usually caused by the auto fill valve going bad or someone opened the manual fill valve allowing too much pressure to build.

    If the pressure relief valve is defective it will trip and spill water.

    If the units control becomes shorted or frozen in the on position the boiler will keep firing and creating hot water when there is no call for heat. This will trip the pressure relief valve also. This last item can be a dangerous situation and in all cases I recommend you call for on site service.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Cold water coming out of hot water tap in bathroom but Really hot water in kitchen [ 7 Answers ]

Can anyone give me a reason as to why nearly completely cold water is coming out of my hot water tap in my bathroom but when I run the hot water tap in the kitchen the water is nearly boiling. The hot water and cold water taps are separate in the bathroom, where the kitchen has a handle which...

Weil McLain Gas Heat & Hot Water Boiler [ 1 Answers ]

What does error code E-19 mean?

Combination Boiler - No water coming out of hot tap. [ 1 Answers ]

Good morning, We've just had a leak in the mains pipe that supplies water to our property. It has been fixed although the water pressure is quite low at the minute (water supply came back 'on' about half an hour ago). My problem now is that although I can get cold water - even though it's not...

Hot water coming from cold water pipe? [ 1 Answers ]

When I turn on the cold water tap, cold water comes out initially, but quickly and momentarily becomes hot for about 30 seconds, then cold again. At the hot water heater, the cold water feed pipe feels cold to the touch when I turn on the hot water faucet - which makes sense and seems normal. If...

How to test gas hot water heater pressure release valve? [ 7 Answers ]

The pressure release valve on the State Select Gas Hot water heater (40 or 50 gallon) is allowing water from the hot water tank to drip through the copper overflow pipe drain on the side of the house. There is no leak or drip around the valve or tank itself. The safety notice on the hot water...