Ask Experts Questions for FREE Help !
Ask
    GLEE2868's Avatar
    GLEE2868 Posts: 1, Reputation: 1
    New Member
     
    #1

    Dec 26, 2009, 06:25 PM
    I have a bryant 397h furnace and the blower will not shut off.replaced circuit board
    I have a bryant 397h furnace and the blower will not turn off.I replaced the control center circuit board and still runs. Any suggestions?
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Dec 26, 2009, 10:14 PM
    Shorted thermostat wire. Label and remove the thermostat wires in the furnace. If the blower stops you have a short in the wiring or the thermostat. If not then it is in the furnace.
    KC13's Avatar
    KC13 Posts: 2,556, Reputation: 99
    Ultra Member
     
    #3

    Dec 27, 2009, 07:09 AM
    Does the system heat otherwise? If so, something may be wired wrong. If not, the primary limit control may be stuck open. Try tapping between the terminals with the butt of a screwdriver. If normal operation is restored, the system may be overheating for some reason.
    Attached Images
     

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Bryant 373LAV Furnace - Blower will not shut off [ 7 Answers ]

Good afternoon all, My question is in regards to the Bryant 373LAV Downflow/Horizontal gas furnace. A good friend of mine called for my help because about a month ago, her furnace blower randomly began running all the time and the only way she could shut it off was to flip the breaker on the...

Blower motor won't shut off on bryant [ 5 Answers ]

Have a bryant furnace 20+ yrs old blower motor won't shut off even after desired temp. is achieved. New thermostat.

Does the board control blower timing and shut down on rudd furnace [ 1 Answers ]

Myfurnace runs too long blowing cold air, does the card control the time or is there another device that does the yellow light blinks

Replaced induced draft blower on Bryant 352MAV is noisy [ 4 Answers ]

A couple of months ago some of you here helped me to diagnose a 3 year old Bryant 352MAV that was giving error code 32. I replaced the induced draft blower and it's working fine. That thread is called "Bryant 352MAV and error code 32" However I'm not sure about the fan on the induced draft...

Blower does not shut off on 15 yr old Bryant heating unit [ 2 Answers ]

The blower on my 12-15 yr old Bryant keeps going ignoring the t-stat stetting. I taught it was the t-stat, I replaced it and it still does the same thing. About a year ago the board was replaced with a newer one that has a fuse (3 amps) And was told that with the fuse it would prevent it from...