Ask Experts Questions for FREE Help !
Ask
    dadams14's Avatar
    dadams14 Posts: 3, Reputation: 1
    New Member
     
    #1

    Jan 30, 2007, 07:46 PM
    Goodman GMPN060-3 Blower Cycles
    I have been in my house for 5 years when the thermostat calls for heat, the inducer blower comes on and almost immediately I hear the pressure switch click and then the relay on the main board clicks and the inducer blower goes off. This happens over and over for a couple of minutes and finally the inducer motor stays on and then the igniter glows and the furnace heats... The furnace would always eventually heat the house. This is way it always worked until this week.. NOw the inducer blower cycles the same way but it never ignites... I hear gurgling when it is running inside the drain trap assembly. I turn the power off for 10 minutes and turn it back on and it may heat for a day, but then it stops ignititng again. I had the service man out and he replaced the pressure switch. For $80 and this did nothing...
    I refuse to call him again, I don't think he understood the furnace at all.
    Should there be gurgling in the drain trap?.
    Is it a pressure switch or a vacuum switch?
    HELP please,
    Thanks in advance
    NorthernHeat's Avatar
    NorthernHeat Posts: 1,455, Reputation: 132
    Ultra Member
     
    #2

    Jan 30, 2007, 08:19 PM
    The drains are partially plugged I'm guessing. A plugged drain will cause pressure switch issues.

    After the furnace has run a while, when the drain can't keep up, it causes the furnace to lock out with a pressure switch fault code.
    dadams14's Avatar
    dadams14 Posts: 3, Reputation: 1
    New Member
     
    #3

    Jan 9, 2008, 03:31 PM
    Quote Originally Posted by dadams14
    I have been in my house for 5 years when the thermostat calls for heat, the inducer blower comes on and almost immediately I hear the pressure switch click and then the relay on the main board clicks and the inducer blower goes off. This happens over and over for a couple of minutes and finally the inducer motor stays on and then the igniter glows and the furnace heats ...The furnace would always eventually heat the house. This is way it always worked until this week.. NOw the inducer blower cycles the same way but it never ignites... I hear gurgling when it is running inside the drain trap assembly. I turn the power off for 10 minutes and turn it back on and it may heat for a day, but then it stops ignititng again. I had the service man out and he replaced the pressure switch. for $80 and this did nothing...
    I refuse to call him again, I don't think he understood the furnace at all.
    Should there be gurgling in the drain trap? ...
    Is it a pressure switch or a vacuum switch?
    HELP please,
    Thanks in advance
    I finally bought a new system board and the problem disappeared.
    Easy fix.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Goodman Furnace -takes 2 Or 3 Ignition Cycles before Stays Running [ 2 Answers ]

Hi,hope you can help me out.i have a goodman manufacturing forced air furnace that i believe is giving me a warning sign of a future failure.what has happened is in this order,1st one morning the thermostat showed that the furnace was on and it was'nt.turned it off and then back on at the...

Ac blower cycles on/off at start [ 4 Answers ]

When the outside temp closes in on the thermostat set temp ( at night ) the ac will cycle on but the blower will try to start then turn off. It cycles like this for a number of times before finally overcoming the issue and then it will run normally. If during this cycling I move the thermostat to...

Heatpump blower cycles on off [ 1 Answers ]

The heatpump works but the blower has problems. When the fan is put to "On", or when the system is initiated by the thermostat, the blower sometimes will try to start, but cycles on/off. I can hear the relay clicking. When the system does operate correctly the problem will eventually re-occur....

Furnace blower cycles with Thermostat off [ 2 Answers ]

Have Goodman Furnace built 1994. Worked fine until about 3 weeks ago. It starts cycling, and the heat icon does not show on the thermostat. I turn the thermostat off, the furnace continues to blow. Last night to verify, took the thermostat off the wall (but still had the furnace plugged in and...


View more questions Search