Ask Experts Questions for FREE Help !
Ask
    cz2clq's Avatar
    cz2clq Posts: 3, Reputation: 1
    New Member
     
    #1

    Oct 3, 2009, 03:08 PM
    Goodman gas Furnace failing to stay ignited
    I have a 9 yr old Goodman GMPN100-4 gas furnace and the unit will not stay lit. The vent fan turns on, it ignites for 6-8 seconds then shuts down. 20 seconds later, it re-ignites for 6-8 seconds, then shuts down. It repeats this 4-5 times, then stops. During this cycle, the vent fan stays on. After the last ignition cycle, the vent fan shuts down. The unit then never restarts. I can reset the power to the unit, and this whole cycle will repeat. I see no blinking from the diagnostic LED on the control board.

    Does anyone have any thought about a failure mode? Thermocouple? But why no blinking from the LED? Anyway, any help is much appreciated.
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Oct 3, 2009, 04:53 PM
    You might try cleaning the flame sensor. They look something like this. Use steel wool or sand paper to shine it up. Easy does it near the ignitor since they can be easily broken and never touch the black/dark grey area of the ignitor.
    Attached Images
     
    cz2clq's Avatar
    cz2clq Posts: 3, Reputation: 1
    New Member
     
    #3

    Oct 3, 2009, 07:55 PM
    That did it. Thanks very much! I saw that and figured it was a thermocouple and thought it was the problem. The absence of a "no ignition" diagnostic code (or any for that matter) had me questioning that. Thanks again!
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #4

    Oct 3, 2009, 08:07 PM
    Glad you got it going.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Goodman furnace comes on but won't stay lit [ 6 Answers ]

Hi my goodman furnace tries to lite but something cuts the gas right back off. Is that the gas regulator? And can I just replace the module on the front of it or do I have to replace the whole regulator? Thanks Brian

I have a goodman furnace that seems to not stay lit. [ 2 Answers ]

I found the same issue or question that was previously asked about a year ago regarding a goodman furnace not staying lit after it power cylcled off 2-3 times. I would like to see the response or answer that Junior________ received. (sorry didn't catch the full name of the asker)

Furnace won't stay ignited [ 3 Answers ]

I have a coleman evcon furnace. It will start with a 30 second purge but then go out. Sometimes it works just fine. What's my problem?

Goodman furnace won't stay lit [ 1 Answers ]

I have a goodman furnace that goes like this. Inducer fan comes on, 10 secs later glow lights up, 10 secs later get blue flames 10 secs later blue flames goes out. Repeats 3 times I have replaced the flame sensor still same problem But here is the thing. I am only getting 10 volts to the...

Furnace won't stay ignited [ 2 Answers ]

We just replaced our thermostat and ever since then the heat will come on and is ignited but still blowing cold air.


View more questions Search