Ask Experts Questions for FREE Help !
Ask
    jwang1's Avatar
    jwang1 Posts: 2, Reputation: 1
    New Member
     
    #1

    Nov 22, 2006, 03:34 PM
    Goodman Furnace won't keep fire up
    I have a Goodman GMP100-5, age uncertain, maybe 6 years. The burner fired up for 7 seconds or so and turned off. After 3 cycles it went off. The status light blinked once. Since the gas fired OK. I replaced the flame sensor. It still does the same thing after the flame sensor replacement. It is a 80% efficiency, forced draft and pilotless unit. A few days ago, the blower fan did come on a few times on its own, with the thermostat turned off. Is it an indication that the control board or the thermostat may be bad? A couple of months ago, when it was in cooling mode, the condensing unit would turn on for a while but would not keep running. I cleaned the thermostat and it worked OK. Suggestions anyone? Thanks a lot.
    labman's Avatar
    labman Posts: 10,580, Reputation: 551
    Uber Member
     
    #2

    Nov 23, 2006, 10:21 AM
    If checking the flame sensor connections to the board doesn't help, I am afraid the board is bad. I hate to see you cough up for a new one and it not be the problem.
    jwang1's Avatar
    jwang1 Posts: 2, Reputation: 1
    New Member
     
    #3

    Nov 23, 2006, 11:48 AM
    Thanks labman. I did check the connection. I guess I have to bite the bullet then.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Goodman furnace problems [ 21 Answers ]

Hi - I have a Goodman GPM furnace. It works intermittently. I replaced breaker, thermostat, Control board and surface igniter. All appears well on start up sequence ; blower runs and igniter heats up and then turns off as no gas comes out. Control board codes says OK. Can anybody recommend what to...

Goodman Furnace [ 2 Answers ]

How old is my Goodman furnace and how efficient is it? Model GUEQ80-4REVS Serial #910482720

Goodman Furnace [ 2 Answers ]

What does A three blink code on a Goodman 80 plus gas furnace mean

Goodman gas furnace [ 3 Answers ]

I have a goodman gas furnace, gms91155dxa for about a year. Recently I notice the furnace repeats on and off while it didn't reach at set temperature. After the heater is on, it runs some minutes and it shuts off itself. And the draft inducing motor runs, the ignitor is on and gas blows and in...

Goodman furnace [ 17 Answers ]

I have a goodman furnace. Forced air. No a/c. I turn the power on and she starts. Thermostat is off. No wires are crossed that are visible. The pilot does not ignite but the heating element is on. No gas seems to be coming through. Any suggestions? The furnace is only a year and a half old.


View more questions Search