    crabbys1's Avatar
    crabbys1 Posts: 2, Reputation: 1
    New Member
     
    #1

    Jan 26, 2010, 12:47 PM
    Goodman furnace problem
    I have two goodman furnaces. They both heat up, but, they both have erratic or uneven sounding flames. They run for a while and then click the flame sensor snap switches off. What would cause this, especially same problem on 2 different units?
    wmproop's Avatar
    wmproop Posts: 3,749, Reputation: 91
    Ultra Member
     
    #2

    Jan 26, 2010, 01:12 PM
    Did you try cleaning the flame senser,, use fine sandpaper or steel wool
    crabbys1's Avatar
    crabbys1 Posts: 2, Reputation: 1
    New Member
     
    #3

    Jan 26, 2010, 01:18 PM

    I have not. I will try and clean them tonight.

    Ty
    Justin Orr's Avatar
    Justin Orr Posts: 24, Reputation: 1
    New Member
     
    #4

    Jan 26, 2010, 04:04 PM

    Also if you can see, make sure the little orifices that shoot the gas out aren't clogged. Over time they may be partially clogged and cause uneven gas flow. Try and clear them out with like a toothpick or something. Check where the flame comes out of too to see if anything has built up.

    Also if they're both run off the same main gas line, maybe there's air in the gas line or some inconsistencies that the city put in there on accident.
    mygirlsdad77's Avatar
    mygirlsdad77 Posts: 5,713, Reputation: 339
    Plumbing Expert
     
    #5

    Jan 26, 2010, 05:08 PM

    Let us know if cleaning the flame sensers work. If not, we will take the next step.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Goodman heat problem [ 5 Answers ]

Goodman NG heater. Cycles to the ignitor, hear a click on the circuit board but no flame. Trouble light stays on steady showing no issues. Have replace circuit board, manually checked pressure switch, checked flo switches.

Goodman furnace GMNT080-4 furnace runs good for a while then has to be manually reset [ 5 Answers ]

I have a Goodman GMNT080-4 (90%). I'm having the same problem As Streatherg did back in the Nov 2006 question. I reviewed his article and tried Every thing on there but seems to be doing the same thing. The furnace kicks on for about an hour then locks out and has to be manually reset threw...

Goodman heater model GMT090-3B problem ignator staying on not droping out after burne [ 1 Answers ]

Goodman heater model GMT090-3B problem ignator staying on not droping out after burner comes on. Have changed board ,checked polarity cleaned flame sensor. Any suggestions.

Goodman gas funace pressure switch problem [ 9 Answers ]

I have a Goodman 93% efficient furnace that short cycles the gas burners. It cycles the vent on, starts the igniter, fires the burners and kicks on the blower but the burners only stay on for a short time ( less than 30 seconds). The led on the circuit board gives me 3 flashes indicating " pressure...

Goodman GMP Problem [ 2 Answers ]

I have a Goodman GMP 100-4 running on propane The last week or so, has seen some intermittent operation. The draft inducement motor comes on but at times no ignition occurs. Vacuum manually applied to the vacuum switch results in ignition taking place. Inducement motor area has been cleaned out....


View more questions Search