    Goodman AC/heat pump
    I have been having problems getting my condensing unit to fire up and the fan I ask earlier and got a response I have 24 volts coming in and I do have 220/240 also but it still will not start?? is their a low or high pressure shut off switch?? I also bought a new thermostat and the new one had a different wiring diagram as follows E,Aux,Y,G,O,L,R,B,C, the wires coming to unit are as follows,Brown,white,yellow,green,orange,red,light blue,where would the white go?? Is it the AUX? Is brown the E, And blue the B, or C?? Not really sure thanks
    acetc's Avatar
    acetc Posts: 1,004, Reputation: 79
    Ultra Member
     
    #2

    Sep 6, 2007, 03:27 PM
    You will need to go to the air handler and remove the access panel to see what wires go where , the white will probably go to Aux. heat, the other wires may go to the outside unit and you will have to see what goes where on the terminal board out side. Good luck.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Condenser Fan Motor Wiring for Goodman AC Heat Pump 3 Ton [ 5 Answers ]

Condenser Fan Motor Wiring for Goodman 3 Ton -------------------------------------------------------------------------------- Hello Everyone, I have a GOODMAN A/C Heat Pump Model# CPLE 36-1 installed 3 years ago. Last week I turned the unit on, the compressor hums (not run)about 3-5...

Goodman AC/heat pump [ 1 Answers ]

I bought a new goodman AC/heat pump unit got it all installed and wired the inside unit fan runs great but the condensing unit fan and pump will not run after the timer goes off the condensing unit has an electrical hum but it won't start?? any idea what going on ?

Goodman Furnace and Heat Pump [ 2 Answers ]

I am shopping for a new HVAC system, have received a quote that sounds very good but I have never heard of a Goodman system. I trust the local dealer. What is the general feeling about Goodman products? My house is about 1250 sq ft, furnace proposed is 90,000 BTU Heat Pump is 14 SEER, located in...

Goodman heat pump (humming) [ 2 Answers ]

My ac/heat pump won't put out cold air. The fan blades on top of the unit turns and runs fine, but the compressor won't kick on. It hums for about 5 seconds every 5 minutes or so. Could my thermostat be to blame or some kind of relay?

Goodman electric heat pump valves. [ 1 Answers ]

I recently bought a house with a 2004 goodman heat pump. During a recent cold spell I learned the referidgerant ran out so I had it filled. Within 24 hours the system was blowing cold air. Another repair guy came out and told me the valve inside the heat pump was broken and could not be...


View more questions Search