    my furnace will not blow hot air, it blows cold air only.
    my furnace does not blow hot air. And the red light indicator stays on continues. My furenace is westinghouse it is 4 years old. And the furnace keeps on working even when I turned off from the in the termostat. I can only turn it off by unplaging the power cord. The wiring diagram in the furnace says 1flash =Limit circuit opens or external load on "W". And I don't know what is the problem or if it can be fix? Can anybody help me with that problem. Thank you for the help.
    T-Top's Avatar
    T-Top Posts: 1,871, Reputation: 100
    Ultra Member
     
    #2

    Feb 17, 2008, 06:24 PM
    One of two things you have a open limit switch or a short in the W circuit. Your roll out limits and vent limit switch will have a button in the center. You have to manually push it to reset it.(small disk above the burners and around the furnace vent inside the unit two wires will go to each one)
    cdx2's Avatar
    cdx2 Posts: 7, Reputation: 1
    New Member
     
    #3

    Feb 19, 2008, 12:56 PM
    Had one yesterday with the same thing. It one of the limit switches. This one was the blower limit switch

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Why does my furnace blows out cold air when it should be blowing out hot air? [ 7 Answers ]

Why does my furnace blows out cold air, when it should be blowing hot air?

My furnace will not blow hot air, it blows cold air only. [ 5 Answers ]

My home furnace is not working properly. It only blows cold air.

Furnace blows hot air for 3 min. Then cold for 3 ? [ 4 Answers ]

Furnace blows hot air for about 3-4 min. (burners all firing nicely) then burners go out but air continues to blow (cold) for 3-4 min. All registers are open and the pressure is VERY strong (small house - 6 ports) cycle repeats about every 10 min. or so. Also, what would the black plastic bucket...

Furnace blows cold air... [ 1 Answers ]

Hi, I'm a new member and thought I had already posted my question, but I can't seem to locate it. So, here I go again. Condensed version: Goodman Gas Furnace... 2years old. Blows cold air. Electronic ignition... ignites flame burners, but they turn off prematurely after about 2-3min. Then after a...

Can't get furnace to blow hot/cold air! [ 4 Answers ]

:confused: I recently moved into a house & I can barely tell that any air is coming out. I have just paid to have all the ducts cleaned. Please help me figure this out.


View more questions Search