    Furnace starting intermittently
    I have a Bryant Plus-80 down draft natural gas furnace. It seems like it is not starting reliably. If I pull the power plug, it will start up when I plug it back in and run normally. However, a few hours later, it is flashing warning or error codes and not running.

    The error codes I have seen are (from the front panel label):
    14 - IGNITION LOCKOUT - Control will reset after three hours. Refer to #34.
    21 - GAS HEATING LOCKOUT - Control will not auto-reset. Check for stuck gas valve relay on control or miswire to gas valve circuit.
    34 - IGNITION PROVING FAILURE - Control will try three more times before a lockout #14 occurs. If flame signal lost after trial for ignition period, blower will come on for 90 second recycle delay. Check for
    -Oxide build up on flame sensor (clean with fine sandpaper)
    -Proper flame sense microamps (.5uA DC minimum)
    -Gas vale turned off - Manual shut-off valve - Low inlet pressure
    -Green wire must be connected to furnace sheet metal
    -Inadequate flame carryover or rough ignition

    Furnace has a White-Rodgers 36E gas valve.

    I have cleaned the furnace and the filter is only a few weeks old. House is about 16 years old, no work has been done on the furnace recently (or at all that I know of, I am not the original owner). Upstairs furnace right next to it works fine, so I don't have any concerns about gas pressure.

    What should I do first?

Check out some similar questions!

My trane furnace blower fan stops intermittently [ 2 Answers ]

I have a 15 year old heat pump and electric furnace I am so proud of it lasting this long with no problems, but the blower motor will stop running about once a month usually when I most need it (meaning maybe it has stopped other times and I have not noticed it.) I can see the unit is still getting...

Carrier furnace turns off intermittently. [ 5 Answers ]

We have a Carrier Weather Maker Infinity 90%+ high efficiency, two stage, NG, forced air furnace that was installed in the summer of 2000. It works great in the summer with our Puron central air unit, however every winter we have the same problem. It turns off intermittently and won't go back on...

Carrier furnace starts only intermittently. [ 2 Answers ]

I had 2 parts replaced on my 20 yr old furnace dealing with the igniter switch. Now the furnace works for several cycles, then eventually, won't restart without manually flipping the switch on the side of the furnace, (which I guess is a reset switch) After flipping the switch, the igniter starts...

Gas furnace ignites intermittently-ignites after removing cover from ignitor chamber [ 3 Answers ]

Unit: Carrier WeatherMaker 9200 gas furnace, with an HSI ignitor Symptom 1: Thermostat is calling for heat, as evidenced by a flame icon on thermostat face, but no action in the furnace. Symptom 2: Ignites only AFTER I initiate Action 2 below. Then it seems to work for a while, until the...


View more questions Search
 

Add your answer here.