    Furnace rheem criterion
    Furnace blower fan and the pre blower fan come on at same time. And the ignitor won't light. Have to turn off power switch to stop both fans. I changed upper limit swith but still won't work. When it was working it was going great, returned and blower was running only but no heat. Thermostat was set high enough to kick it in but still the fans would blow but no ignition. Ignitor is the glass type inspected for cracks but looks good. I just replasced last year.
    NorthernHeat's Avatar
    NorthernHeat Posts: 1,455, Reputation: 132
    Ultra Member
     
    #2

    Jan 28, 2008, 03:10 PM
    A roll out limit tripped, look for small disk devices around the burner. They have a small red button between the two wires, gently push the buttons until it clicks, or check all the limits with an ohm meter to find out which on went bad.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Rheem criterion II gas furnace [ 1 Answers ]

It is now about 57 degrees in my house. My furnace just turned on but there was no ignition, no flame. I could hear the blowers running. Is my flame sensor bad or dirty? Or is it something else? How do I fix this? I have fixed my furnace before with a new flame sensor or something like that. I...

Do you know the rheem criterion 2 (RDGD 05MAUER) [ 4 Answers ]

Anyone know the rheem criterion 2 (RDGD 05MAUER) , if so could you see my post with pictures on here https://www.askmehelpdesk.com/heating-air-conditioning/heater-fine-daytime-stops-night-159346-new.html I can't figure this out, all the details there if u browse over the posts and reply...

Rheem criterion II gas furnace [ 3 Answers ]

Have a rheem furnace and when it turns on it blows real hard something I read said it has a three or four speed motor just wondering if some one could help me change the wires to lower the speed of the motor

Rheem criterion furnace [ 3 Answers ]

My air went out yesterday and I don't what to do... the motor outside is not working but the inhouse fan is work air is coming out of the vent but it is not cool. This happened in the winter and we had the heat ignaitor replace... help?? it 98 degree today

Rheem Criterion Furnace fan keeps coming on and off constantly with loud noise [ 14 Answers ]

Rheem Criterion Furnace fan keeps coming on and off constantly with a loud noise. Can someone please help me? Paul::confused: