    Furnace burning up transformers
    Nordyne E2EB-015HA
    No power to tstat. Traced problem back to transformer. Only 3v on secondary. Replaced transformer & consistently have 243v primary & 26v secondary. Fan works fine. Cool works fine. As soon as heat is turned on transformer starts popping & burning up.
    What would should I check next?
    Stratmando's Avatar
    Stratmando Posts: 11,188, Reputation: 508
    Uber Member
     
    #2

    Nov 15, 2017, 08:18 AM
    Either the Heat wire is shorted, or Contactor/Relay Coil is shorted.
    Try removing the low voltage wire at the coil of heat contactor, and try again, if it doesn't blow, it is the relays coil, Maybe add a 3 amp blade fuse holder first to protect the transformer. 40 VA? Good Luck

Not your question? Ask your question View similar questions

 

Add your answer here.


Check out some similar questions!

RUUD Silhouette Furnace/AC UNit Burning up 24v transformers [ 1 Answers ]

I have a 10 yr old Ruud unit that has blown (2) 24vac 40va transformers. Can Anyone tell me what might be causing it. The first one was the original, the second one didn't last the night. Help Please. Thanks

RUUD Silhouette Furnace/AC UNit Burning up 24v transformers [ 1 Answers ]

I have a 10 yr old Ruud unit that has blown (2) 24vac 40va transformers. Can Anyone tell me what might be causing it. The first one was the original, the second one didn't last the night. Help Please. Thanks

Burning Up 24V Transformers on a newer Bryant Oil Furnace [ 4 Answers ]

We have a 3 year old Bryant Oil Furnace, Model 369AAN series "C", that recently started burning up the 120/24 volt coil. The 120/24V coil powers the thermostat. We've burned up two coils within the past two days and am getting ready to repace it for the third time.

Furnace Transformers [ 1 Answers ]

Train furnace blows 24 volt transformers new original and a new replacement what could cause this and what to check for next


View more questions Search