    Furnace blows hot air for 3 min. then cold for 3 ?
    Furnace blows hot air for about 3-4 min. (burners all firing nicely) then burners go out but air continues to blow (cold) for 3-4 min. All registers are open and the pressure is VERY strong (small house - 6 ports) cycle repeats about every 10 min. or so. Also, what would the black plastic bucket full of water (20gal. Or so and half full) and connected to furnace be? Appreciate any info. Thanks
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Jan 3, 2008, 09:53 AM
    Does this furnace vent outside with PVC pipe?
    therinnaiguy's Avatar
    therinnaiguy Posts: 153, Reputation: 5
    Junior Member
     
    #3

    Jan 3, 2008, 10:03 AM
    Drain the bucket, it's the poorman's way to catch condensation from the furnace. The correct way is to install either a gravity drain or a condensate pump to rid the furnace area of this acidic water. This may solve your issue. If not clean the flame rod or sensor with a stiff brush or steel wool. The sensor looks like a rod and is usually found next to or in front of the burner. Do not mistake the igniter as the flame rod. The igniter will have two wires going to it and may be very brittle even to the touch. Prior to doing this, cycle the system and note which component glows orange prior to lighting. This will be the igniter.

    The water is a byproduct of combustion. Your system is a high efficiency unit and instead of a lot of water vapor being expelled from the vent, it is being displaced as water. This is a good thing and yo are probably getting 90% or more efficiency out of it.
    HiBotan0789's Avatar
    HiBotan0789 Posts: 2, Reputation: 1
    New Member
     
    #4

    Jan 3, 2008, 01:07 PM
    Quote Originally Posted by HiBotan0789
    furnace blows hot air for about 3-4 min. (burners all firing nicely) then burners go out but air continues to blow (cold) for 3-4 min. All registers are open and the pressure is VERY strong (small house - 6 ports) cycle repeats about every 10 min. or so. Also, what would the black plastic bucket full of water (20gal. or so and half full) and connected to furnace be? appreciate any info. thanks
    Yeah HVAC1000 - its vented outside with 2 separate 3" white pvc pipes. therinnaiguy-As far as the bucket goes, can't drain it cause it seems to be plumbed into the furnace (theres no drain located on it) Looks to have a pump inside it though just no where to pump the water into. I'll try draining/pumping and cleaning the flame rod. Many thanks
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #5

    Jan 3, 2008, 04:41 PM
    I asked about the PVC pipe to see if it was a high efficiency furnace. Check and if necessary replace the pump or find a way to drain the furnace. It is a bit hard to believe someone would have used a bucket system but If there is no drain I guess it is just like using a condensation pump for A/C.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Gas furnace blows cold air [ 10 Answers ]

Hi. I have a gas furnace, not sure of the brand. It is blowing cold air. When I watched it go 'on' before, here's how it generally works - the pilot light ignites, then generally several seconds later the furnace 'catches', makes a low rumble and starts sending warmer air through the vents. ...

Gas furnace blows cold air [ 1 Answers ]

My furnace is a carrier and it is pretty old. It works most of the time , but it seems to blow cold air every time it rains and once is dries up it works fine again. I need to either buy a new one or get this one fixed before winter sets in. any suggestions?

Furnace blows cold air [ 3 Answers ]

Yesterday my furnace stopped heating my home. It is 3 years old & I did some minor troubleshooting. The filter is not clogged and the blower is circulating air normally. I checked inside the unit & the ignitor coil is heating and starting the gas jets burning, but they shut off after about 10...

Please help:Furnace still blows cold air... [ 2 Answers ]

Hi again, I posted my situation a few days ago with very little response, so I wanted to follow up again before calling out a technician. I have a Goodman gas furnace, about three years old. It has electronic pilot ignition, which works fine and will enable the burner flame... the problem is the...

Furnace blows cold air... [ 1 Answers ]

Hi, I'm a new member and thought I had already posted my question, but I can't seem to locate it. So, here I go again. Condensed version: Goodman Gas Furnace... 2years old. Blows cold air. Electronic ignition... ignites flame burners, but they turn off prematurely after about 2-3min. Then after a...


View more questions Search