    Furnace Blower
    Two months ago I noticed furnace blower would switch off after being on a couple of minutes. Once I heard some humming, thought it was the motor. Had a techinician diagnose it, he said it was the blower motor, a $400 repair. I pulled it out myself, took it to a electric motor shop. They put power to it, it worked and they said to replace the capacitor and sold me one for $15. I also oiled the motor via the oil ports. Things worked fine for 2 months, then I noticed it wasn't coming on again. Sometimes it would work sometimes not. No humming this time. Once I tripped the thermostat and it took 20 minutes before it came on. Next time it didn't come on I turned the manual fan switch at the thermostat on and I left the main furnace switch on and used a test light at the junction box on the blower to see if it was getting power and it was. I tried turning the power switch at the furnace on and off and didn't get any sound or response. I pulled the blower out, applied power and it ran the squirrel cage for 10 minutes without overheating and with no scrapes, squeaks, moans or groans. I called the HVAC company and they said the motor may be pulling too much power when installed due to pulling air through ductwork. I can't spend unnecessary funds! I can get the motor replaced at the motor shop for $150, but is it something else??
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Oct 12, 2006, 04:21 PM
    Could have a dead spot in the motor or could also be a control problem. If you have an Amp probe you can check current draw and compare it to the rate plate on the motor if not you will have to roll the dice or call the service man back and get it fixed correctly.
    prathman's Avatar
    prathman Posts: 2, Reputation: 1
    New Member
     
    #3

    Oct 13, 2006, 09:17 AM
    I would check what voltage is actually getting to the blower motor when it's installed. You might have a contol or wiring problem that results in the motor getting less voltage than it needs to run.
    labman's Avatar
    labman Posts: 10,580, Reputation: 551
    Uber Member
     
    #4

    Oct 13, 2006, 09:34 AM
    As above, the power may not be making it through the furnace controls to the motor. Likely the relay on the control circuit board is bad. Unfortunately the cheap, little, failure prone relays are hard to diagnose and replace without a whole new circuit board. $$$$$$$$$ Flaky relays are even harder to diagnose.

    One thing you could do is check for power in the wiring to the motor when it won't run. I would use my voltage detector for that.

    To do simple checks like this you do need some tools. A test light, a meter, or a voltage detector might be the best place to start with. I came across the niftiest gadget for trouble shooting, a voltage detector. They work through the insulation of wires. There are several brands. I have a GB Instruments GVD-505A, less than $15 at Home Depot. Touch it to a hot wire, and the end glows red. Find the doodad that lights it on one side, and not the other, and you have the culprit. You do not have to open up housings and expose electrical contacts. You are looking at where your hand is, not where the meter is. Most people are capable of doing repairs and will get it going and not get hurt if they use a little sense. The voltage detector makes it even easier.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Furnace blower motor [ 10 Answers ]

I have a Climatrol Furnace, and it stopped working. I called a Heating Co, and the technician said that that the motor was bad, it's and old unit with Climatrol no longer in business. I might be able to find a used motor, but I really need a new furnace. After he left I was reaching in and I was...

Furnace blower won't turn on [ 8 Answers ]

I have a Bryant 395C furnace. The blower won't come on even when thermostat fan switch is set to "on." I've verified that I'm getting 24V AC between terminals marked G and C on the furnace. Blower has 3 wires going into circuit board on furnace. These are colored red, black, and white; red is...

Furnace blower? [ 3 Answers ]

This morning my furnace in the attic was making some weird sounds. By lunch time the was a burning smell through my vents. At lunch time no heat was blowing through my vents in the house. I turned the a/c on and still nothing. My unit outside is working fine too. What do you think it could be?

Furnace blower on manual [ 4 Answers ]

Our installer told us to run our air blower on manual and continuously. During the winter months, it seems to make the house "drafty" by pushing unheated air through the system when the furnace is not running. He also said that the cost of running the blower would be negligeble. What are the...

Furnace/blower. [ 6 Answers ]

Been searching but so far I haven't found any information that really helps me. I've lived in this house for about a year and a half now, it has the original furance in it(house was built in the 70's I blelieve). Last year the furnace worked fine, and had worked fine so far this year. I live in...


View more questions Search