Ask Experts Questions for FREE Help !
Ask
    pearson2's Avatar
    pearson2 Posts: 8, Reputation: 1
    New Member
     
    #1

    Dec 17, 2008, 06:51 PM
    Flashing indicator 6-115 volt ac power reversed improper ground.
    I installed a 50A50-241 with a universal replacement part 50A55-843. All the connections were easy enough to transfer till I got to a white wire in slot E21 on the original Model. The replacement does not have a slot E21 and I am getting the following error message:
    115 volt ac power reversed improper ground. Can anyone suggest what I need to fix this problem? Thanks
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Dec 17, 2008, 10:32 PM
    Here is a touble shoot procedure.

    http://www.white-rodgers.com/wrdhom/...pg0259_264.pdf

    Pay attention to this note on page 1


    A. Check continuity for C terminal on module to electrical service ground and
    connection at the furnace junction box. If ground connection is open, check
    module ground connection and the electrical service ground connection.
    Repair and retest.
    B. Re-connect electric power to system.
    C. Check for voltage between the line neutral terminal and furnace ground. If
    voltage exists, the main power supply lines are improperly connected to the
    furnace (REVERSED POLARITY). Again disconnect electric power to system;
    then reverse incoming supply leads to furnace. Repeat step.
    D. Recheck system for proper operation.

    See LINE and LINE N on page 4 here. Those are the leeds reversed. See below for this


    http://www.white-rodgers.com/wrdhom/.../0037-6265.pdf

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Flashing indicator 6-115 volt ac power reversed improper ground. [ 8 Answers ]

I installed a 50A50-241 with a universal replacement part 50A55-843. All the connections were easy enough to transfer till I got to a white wire in slot E21 on the original Mode. The replacement does not have a slot E21 and I am getting the following error message: 115 volt ac power reversed...

Hot/Ground Reversed? [ 3 Answers ]

I've got a GFCI receptacle and a regular receptacle powered respectively by two different circuit breakers from the same power panel. When the circuit breakers are switched on, both receptacles have 120 VAC at their outlets and read "Correct" on a circuit tester. Now, when I plug my TV or...

Hot/Ground Reversed [ 5 Answers ]

:confused: Can you have lights and outlets coming from two circuits (i.e. two breakers from the main box)? Also how do you reverse the ground and hot wire? I am wanting to move a light switch... I went to the breaker box and turned off the power to that circuit. I proceeded to disconnect...

Hot and Ground Reversed [ 1 Answers ]

I went into a house today and my little plug in said I had a Hot and Ground Reversed. I popped open the box and took a look. Black to copper and white to silver. Everything OK there. Ground was present,terminated correctly and not touching the hot. My question is what is hot and ground reversed?...