Ask Experts Questions for FREE Help !
Ask
    stevenriz's Avatar
    stevenriz Posts: 2, Reputation: 1
    New Member
     
    #1

    Feb 9, 2007, 09:48 AM
    Faulty Relay in Furnace
    Hi everyone. My Concord two zone oil fired forced hot air furnace decided to stop coming on the other day. It has a Honeywell EMM-3 zone controller, a relay and a transformer. I had my oil dealer come and look at it, it was working for him. After he left, it stopped again. I took matters into my own hands as I am technically inclined especially with wiring. I replaced the zone controller. The furnace ran one cycle to satisfy the thermostats and shut off normally. Once the thermostats called for heat a second time, nothing. The zone controller shows the furnace is on, but it really isn't. So I replaced the transformer myself. Turned it on, Same thing. Once cycle charlie I call it now. That leaves the relay. Do you agree? Anyway, the transformer came with a relay, I just took it off and put it aside. Now I want to try and use it, but the posts do not match up to what I have in there now. Are there different relays that I can get that will match up better? It's like the relay that is in there now has posts that are missing on the new one and vice versa. I am not worried about heat, if I need heat, I just go and tap the relay with a screwdriver and it kicks the furnace on :-/

    What do you guys think? Are there different relays that I can get that I can just pull a wire from one and put it on the other so I don't screw it up?
    Steve
    stevenriz's Avatar
    stevenriz Posts: 2, Reputation: 1
    New Member
     
    #2

    Feb 9, 2007, 11:47 AM
    My furnace guy was telling me that I probably should have had two transformers and relays hooked up. It might be that the singel relay is getting weak and wearing out in other words. Sort of makes sense. I told him "your company is the one that installed this thing, can I blame you?? Of course not he said haha. We'll see...
    labman's Avatar
    labman Posts: 10,580, Reputation: 551
    Uber Member
     
    #3

    Feb 9, 2007, 12:27 PM
    I would give making the relay you have work if it matches the requirements. Most relays have 4 terminals, line, load, and 2 coil terminals. If the coil and switched voltage are the same, sometimes line is combined with one coil terminal. So identify the coil terminals. One connects to the white wire from the zone controller and the other to the common of the transformer. Line connects to the incoming power, and load to your blower or damper. As long as you sort out the coil terminals from line and load, it should work.

    One complication is a double throw relay. Line connects to com. It will be connected to the NCC terminal until the coil is energized. It them switches the common from NCC to NOC. If the old relay only had line and load, chances are the new one will work if you connect them to com and NOC. Some zone systems must have double throw relays.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Faulty Furnace [ 2 Answers ]

Dear Sir/Madam: Hello, I stared a furnace that has not run in over a year. Initially it fired up fine and ran for awhile. I shut it down and did not fire anymore. The blowers were working but the igniter did not glow. I tested for low and high voltage and realized the transformer had shorted out....

Faulty wiring [ 6 Answers ]

I have a problem with wiring in the kitchen. It's a faulty switch that stops working intermittently and seems to heat up and crackle from time to time. It powers the washing machine so I really need to use it. Also there's a light on it and also I can't switch it off, the switch seems to be stuck...

Faulty FSB [ 1 Answers ]

I have a server that blue screens when it starts to get into Windows Server 2003. The only perculiar thing is that it only does it when the FSB is set to 133MHz. If I turn it down to 100MHz it loads and runs fine. I am yet to try a BIOS upgrade on the motherboard as I am running a repair on the...

? Faulty wiring [ 4 Answers ]

:D - hello first post, so hoping that you are far better than I when it comes to electrics! Have just moved into a new house and could not believe that the previous couple had not left bulbs in the front room. One electric shock later and I now know why- none of the electric lights turn off at the...


View more questions Search