Ask Experts Questions for FREE Help !
Ask
    cassiejim's Avatar
    cassiejim Posts: 5, Reputation: 1
    New Member
     
    #1

    May 30, 2012, 04:45 PM
    Fan motor over heats and shuts down while A/C keeps running
    I have replaced the furnace motor and capacitor and the motor continues to heat up and shut down while the A/C continues to run. How many hours can the fan motor run without heating up and shutting down?
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    May 30, 2012, 06:10 PM
    Quote Originally Posted by cassiejim View Post
    I have replaced the furnace motor and capacitor and the motor continues to heat up and shut down while the A/C continues to run. How many hours can the fan motor run without heating up and shutting down?
    If installed correctly the fan motor should run almost forever OR until the power to the fan is stopped.

    Check to be sure the fan is turning in the correct rotation. Running in reverse will lower the air flow and also make the motor overheat.

    Make sure the motor is wired according to the diagram on the new motor itself. Many times people will just wire it the way the old one was wired and that can be a problem.

    Make sure the motor is of the correct voltage and horse power as the old one . A little larger horse power motor is OK.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Central air conditioning units fan motor stop running has new motor [ 0 Answers ]

Central a c unit fan motor stop running has new motor and capacitor

Ac motor for condenser fan shuts down [ 6 Answers ]

Just replaced ac /Motor on condenser fan shuts down after gets hot had three wires new one has to need help it comes on blows good cold air then gets hot shuts down after about 10 minutes maybe wiring is that it is wrong him please help

Fan motor heats up then freezes [ 2 Answers ]

Why does the motor heat up then cease

Air Exchange in house running, outside motor running, Fan not turning [ 0 Answers ]

I have a RUUD #UAKA-024JAS man. 1995. The exchange in the house functions. When I turn the AC on the motor is running, but the fan isn't turning. I checked the breakers, which seemed to be fine. I disconnected the power and checked the fan, which spins freely. I need advice on how to fix this...