    Does the Goodman GMH950703BXAC have an ECM motor?
    I replaced a 40+ year old furnace in October with the Goodman GMH950703BXAC.
    I applied for the rebate from Consumers Energy and they said it did not have and ECM motor and wasn't eligible. Can anyone explain if they are correct or incorrect?
    KISS's Avatar
    KISS Posts: 12,510, Reputation: 839
    Uber Member
     
    #2

    Jan 13, 2010, 02:13 PM

    Goodman GMH950703BX Gas Furnace 69,000 BTU Furnace, 95% Efficiency, 2-Stage Burner, 1,200 CFM Multi-Speed Blower, Upflow/Horizontal Flow Application

    Says it qualifies for the Federal Energy Credit. I think someone is pulling your leg because it's a 95% efficient furnace.

    Now if it wasn't professionally installed or not within the timeframe, then that's an issue.

    Page 13 of http://www.alpinehomeair.com/related...eet%206.09.pdf

    Looks like it's a PSC motor for the blower. The GMV or GME have the ECM motors. See page #2.

    An ECM motor saves electricity. It probably isn't counted in cumbustion efficeincy.

    There is a list somewhere on a Federal site as to which systems qualify for the Federal tax Credit. If you arm yourself with that info, you may win UNLESS this is an electric only issue with the energy provider.

Not your question? Ask your question View similar questions

 

Add your answer here.


Check out some similar questions!

Goodman inducer motor [ 2 Answers ]

Hi, I live in near Nashville, Tenn. I have a Goodman HVAC unit model PG036100-1B REV E (gas furnace and A/C unit) over 20 years old. It started to make a very loud grinding noise when the furnace came on, so I had it inspected by a local HVAC repair company, and the tech said the inducer motor is...

Goodman furnace will ?heat motor? And blower motor will run but not at same time [ 2 Answers ]

I have a 2 year old Goodman, gas, no heat pump. There is a flashing LED that blinks once ever 4 seconds. Also, blower motor does not stay on always. We did smell something like an electrical burn. I'm guess my blower motor is fried?

Goodman Inducer Motor [ 18 Answers ]

I have a Goodman Gas Furnace installed in 1997 and have been experiencing the following problems: The usual run for the furnace has been inducer motor on, ignition (with flames), and then the blower motor comes on. I have been having the inducer motor come on, run for about three minutes,...

Goodman furnace ECM motor blowing too much air? [ 5 Answers ]

I installed a Goodman GMV95 two speed gas furnace with ECM fan motor last fall. It functioned perfectly last winter, cutting my natural gas bill almost in half. When I installed the unit, I set it for 720 cfm (my ductwork is a little small for 95% efficient equipment) and verified the airflow by...


View more questions Search