Ask Experts Questions for FREE Help !
Ask
    TinkererTerry's Avatar
    TinkererTerry Posts: 4, Reputation: 1
    New Member
     
    #1

    Feb 4, 2009, 09:52 AM
    DESPERATELY need testing and part answers for Reznor
    I have a Reznor F100 ser# ANK31k5n65696, Natural gas, manufactured Nov. 1988. Since that time it may have run 90 days total. I have tested the transformer, it appears the 120 side is bad. I have pulled the three sensors so that they can be tested (once I know how)

    In researching a new transformer in Reznors part cat. At:

    https://www.rezspec.com/index.php?pa...0012&mod_files[currpos]=000000000054&mod_search[text]=P-F%2FB&mod_search[skipsearch]=true

    Then you ([F]If you want to see the parts I am talking about --- Middle of page ) select:
    P-F_B.pdf... Replacement Parts - Model Series: B, BE, F, FE Unit Heaters

    On page 19, They reference "F 25-400 Single-Stage, March-Lit Pilot" uses a "115/1/60, 12VA, Basler #BE141615-RAD Part No. 131988 replaces part 102706"
    OR
    "f 75-400 Two-Stage, Match-Lit Pilot" uses a" 115/1/60, 20VA, Basler #BE141620-RAD, 132204, replaces part 102709".
    Since the part number on the existing transformer - Reznor 96346-class 2 60hz, TE121224-B11, pri bk-yw120v, sec 25v 12va, do not match any of the choices, am I correct in picking: 115 1 60,12va, Basler #BE141615-RAD ?

    Having replaced the gas valve and pilot assembly ([F]the starting problem being pilot would not stay lit) to no avail, as I see it, there are only three other parts left to replace: (All on page 18) the ECO device that goes to the valve near the pilot gas supply, - replacement part #82414; limit control, auto reset - replacement part #45602; and fan control assembly - replacement part #123976(the old numbers don't match but it does say 150-35f)
    Is there a way to test these 3 items so I can put in one order and be done? I built a scaffolding over the chest freezer a couple weeks ago to get to the control side of furnace(to old, to fat, to ridged to hang sideways from ladder) I am in the better half's way and she is starting ask if I am ever going to get done working on that piece of junk!
    Thanks Terry
    wmproop's Avatar
    wmproop Posts: 3,749, Reputation: 91
    Ultra Member
     
    #2

    Feb 4, 2009, 01:47 PM
    If I`m looking at the right one,, it looks like a standard 120/24 volt step down transformer which is universal except maybe for the mounting base ,which can be altered to work,, these can be bought at any heating /cooling parts house,,
    Hondo0302's Avatar
    Hondo0302 Posts: 1, Reputation: 1
    New Member
     
    #3

    Jan 24, 2011, 08:54 PM
    I have 2 model F heaters. I found shorting VCO device with a cliplead allows pilot to stay lit.
    Danny Sadler

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

70's movie part live action / part cartoon [ 3 Answers ]

It was about a boy who found a dragon (the dragon was the cartoon part) and a family tried to take it away from him. They were trying to make a profit off him or something. Its characters look run-down kind of like chimney sweepers back in the day.

Desperately Need some answers about Irregular Periods [ 1 Answers ]

Please Help!! I am a 20yr who just saw a gyno. I saw him because I have an irregular cycle that lasts anywhere from 1 - 3 months and I am trying to get pregnant. I tried to ask him about the possible causes for my irregular cycles but he wouldn't even give me any suggestions. All he did was put me...

Two part tenant question seeking answers! [ 2 Answers ]

I apologize beforehand for the novel but the details are pertinent. Presently, I am using my home of six years for shelter for my 3 children and I. Our time here is extremely limited as our landlord lost the house in foreclosure. I have been to court for unlawful detainer and lost to the mortgage...

Spouse outside US for part and in US for part of the year - file single or joint ? [ 1 Answers ]

Hi, I have been working in the US (RI) since Aug 2006. My wife has been living and working in India all this time. However, in Aug 2007, she came to the US (CA) on an independent work visa. For financial year 2007, would it be beneficial / correct for us to file taxes individually or jointly...