    Day & Night furnace
    How do we clear an IGNITION LOCKOUT FAULT?
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Jan 5, 2008, 01:09 PM
    Turn all power off. Wait a minute and re energize.
    valirock's Avatar
    valirock Posts: 2, Reputation: 1
    New Member
     
    #3

    Feb 24, 2008, 09:17 AM
    Quote Originally Posted by hvac1000
    Turn all power off. Wait a minute and re energize.
    The blower fan comes on immediately when I plug the unit, but the ignition doesn't start.
    How can I reset the unit?
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #4

    Feb 24, 2008, 12:02 PM
    The blower fan comes on immediately

    Sounds like the high limit is tripped. If it is and has a red button in the middle of the disc reset by pushing the red disk. You migh also have a different problem if your unit has a roll out device in the burner area. Those cannot be reset but replaced.

    NOTE make sure your thermostat is not set to fan on.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Gas furnace blows out cold air at night [ 3 Answers ]

Hi there. I have a problem that I haven't quite seen here and I have no idea how to search for it. Here's the deal: I have a gas furnace. I'm trying to save energy, so I got a new thermostat at the beginning of the fall. I set it to 68 when we're awake and in the house, and 60 after 10pm and...

Furnace runs sporadic - on and off all night [ 10 Answers ]

I have an older furnace (20+ years) and it is keeping us up at night. We had some extra ducts put in when we finished the basement and at the time we were right at the edge of what the furnace could run (it is approx 55% effecient). The house is always cool and not a lot of heat reaches the...

Self test OK, but no heat from day&night forced air furnace [ 8 Answers ]

So this morning I cleaned the filters and turned power off to the furnace. Now power is back on, self test passes (inducer, igniter, humidifier relay (no humidifier hooked up), blower high, blower low), but when I put it back in operation heat does not come on - just th 'inducer.' the igniter...

Day & night furnace not igniting [ 1 Answers ]

Hey all: I have a '73 Day & Night furnace that won't ignite after being shut down for the season. I have a pilot light and the unit reponds to the thermosat, at least the blower kicks on. I have seen a couple of things that might be possible fixes and wanted some other opinons. 1 -replace...


View more questions Search