Ask Experts Questions for FREE Help !
Ask
    chastap's Avatar
    chastap Posts: 1, Reputation: 1
    New Member
     
    #1

    Jan 23, 2007, 04:33 PM
    Convert blower fan to run slow
    What I would like to do is convert my furnace fan to be able to run at a slow speed all the time to continually move the air through out the house janitrol furnace:confused:
    rickdb1's Avatar
    rickdb1 Posts: 185, Reputation: 15
    Junior Member
     
    #2

    Jan 24, 2007, 08:13 AM
    Quote Originally Posted by chastap
    what i would like to do is convert my furnace fan to be able to run at a slow speed all the time to continually move the air thru out the house janitrol furnace:confused:
    The lowest blower speed possible will be achieved by using the red wire from the blower motor to the fan control. What wires are hooked up now? Low speed would not be recommeded for A/C usage, as it requires more airflow over the cooling coil to get the proper pressure/temp relationship... Most fairly modern furnaces automatically switch to low(Or medium) for heat and high speed for A/C operation...
    NorthernHeat's Avatar
    NorthernHeat Posts: 1,455, Reputation: 132
    Ultra Member
     
    #3

    Jan 24, 2007, 02:56 PM
    I wouldn't suggest using low speed for heat either. Changing blower speed won't accomplish much for a split phase motor except reducing noise from air turbulance. Operating cost will still be very much the same.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Fan on lennox furnace won't run [ 4 Answers ]

Hello I have a 20 year old Lennox Conservator 3... gas furnace/AC combination unit. The problem started as: When I set the thermostat to "heat" and fan on "auto", the burner would light and stay on for a few minutes then shut down (as it is supposed to do) because the fan was not coming on....

Blower Fan noise / slow to start [ 3 Answers ]

Last night I heard a rumbling noise coming from the closet in the hallway where our Trane XE80 gas furnace (April 1996) is located. With the door open the noise appeared to be coming from the blower area. We are in the heat of summer so, to stop the system, I set the temperature on the...

AOL is starting to run very slow [ 1 Answers ]

I have verizon DSL and whenever I try to go to AOL mail. My computer takes about a minute before anything happens. I have deleted my temp int files and cookies. What else could be causing my comp. to start running so slow?

How to make fan run auto [ 6 Answers ]

Hello, I have been trying to browse the website, trying to find out how to wire my t-stat so that it will run on auto.. I have 24v transformer, red, and white, and I connected it to the back of my t-stat, the fan turns on only when it turn the t-stat switch to heat no auto or on function. however...

Run blower without heat? [ 2 Answers ]

Hi, I have a weather king propane furnace. I do not know the age. I have a simple dial thermostat. I would like to figure out how to run the blower without the heat. The wires from the thermo going into furnace have the three wires but the green is not connected to anything. The red is connected...


View more questions Search