    Condenser using R22 can be retrofit with coil using R410A?
    I am planning to replace the furnace. The technician from Trane is advising me to replace both furnace and coil as the coil was installed when original heating and cooling system was installed back in 1972 when it built. Last year, I replaced the condenser (with Trane high efficiency condensor). This condenser uses R22. Reason he is siting to replace the coil is if coil fails down the road more that likely I won’t be able to get a replacement, then the only option would be to replace both the condenser and coil.

    1. What is the average coil life?
    2. If coil fails, then I will be required to replace both coil and condensor (as R22 will be phased out in 2010) and probably coils using R22 will not be avilable in the market?
    3. The condenser using R22 can not be retrofit with coil using R410A?
    4. He is providing 5 years warranty (cost $209.0) on "Parts and Labor", is it worth to take it?
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Oct 6, 2009, 12:46 PM
    What is the average coil life?

    There really is no average coil life except to say it is always smart to replace the indoor coil when replacing the outdoor unit. This is said more for energy savings than anything else since the SEER ratios change every so many years for the better.

    If coil fails, then I will be required to replace both coil and condensor (as R22 will be phased out in 2010) and probably coils using R22 will not be avilable in the market?

    NO a R-410A rated coil will be able to be used on a R-22 system with no problem so you will be able to replace your old coil in the future without replacing the outside unit.

    The condenser using R22 can not be retrofit with coil using R410A?

    You cannot use R-410A refrigerant in a R-22 unit. No retrofit is possible due to design pressure limitations. But you can use a R-410A inside coil on a R-22 outside unit since the R-410A coil is rated for a higher pressure operation than R-22 will expose it to.

    He is providing 5 years warranty (cost $209.0) on "Parts and Labor", is it worth to take it?

    Is this on the replacement furnace? If so the parts are probably guaranteed for 5 years to start with but the labor warranty seem to be worth it if you feel he will be in business for 5 years. Read the factory warranty and then decide.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Replacing R22 with R410A [ 9 Answers ]

I have several proposals for the installation of a new, more energy efficient HVAC system for my home. The company reps from Trane are telling me that they will need to install new refrigerant lines for the R410A because they can't remove all traces of R22 from the current lines. Lennox reps say...

Replacing R22 with R410A system [ 2 Answers ]

I replaced my current Heat Pump system that uses R-22 with new one that uses Puron (410A). The system I got is : Carrier 25HPA542 (preferred series) Heat pump Carrier FE4 (infinity series) Air Handler Carrier Infinity series Thermostat My question: I am using the existing lineset ( as...

Hole in AC condenser cooling coil [ 3 Answers ]

My home AC unit is not cooling. I thought the compressor was not working, I had the capacitor checked out and it is good, I cleaned the contacts and when I reinstalled it and turned the system on I discovered a small hole on the coil, since the line is not charged (all freon leaked out) I couldn't...

Mismatched condenser & Coil [ 6 Answers ]

My house is 3400 Sq Ft. 8 years old, 2 story. Each unit is 2 1/2 ton, Rheem Heat Pump units. They have been working very well. I can get about 22 degree difference downstairs and about 19 upstairs. I have added extra blown insulation in the attic. Roughly about 36", with a power fan and whirly...

New Outside Condsing Unit, Bad indoor Coil - Go with Heat Pump or Buy New Coil? [ 7 Answers ]

Hi All, Here is my issue. Recently, our home warranty company paid to replace a 25 year old 7 SEER Borg Warner outside unit, but swore up and down that the indoor Borg Warner Coil would be OK with the new 10 SEER Carrier. We no longer have this home warranty company and they are not standing...


View more questions Search