    AmatuerAC's Avatar
    AmatuerAC Posts: 1, Reputation: 1
    New Member
     
    #1

    Oct 24, 2010, 06:06 PM
    Condenser Contactor Switch
    I have a Lennox condenser model Number 13acd-042-230-01. The contactor switch does not stay in. It pulls in, the fan runs, the compressor kicks on and then within two minutes it pops out.
    I have cleaned the contactor switch with electrical contact spray and replaced the thermostat with a brand new one. That did not work.
    Stratmando's Avatar
    Stratmando Posts: 11,188, Reputation: 508
    Uber Member
     
    #2

    Oct 24, 2010, 06:18 PM

    You should have 24 volts at contactor for it to stay in, check voltage at contactor coil to see if 24 volts is present when it deenergizes.
    I wonder if contactor has shorted windings drawing excessive current.
    Also I would suspect low voltage wiring from air handler to compressor unit, any short may draw excessive current?

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Replaced condenser fan, dual cap, contactor and still... [ 4 Answers ]

Here's the scenerio... Yesterday afternoon, my condenser fan stopped running, but I could hear my compressor running and the relief valve was hissing. Made a trip to my favorite supply warehouse, picked up a new fan motor and dual cap. Installed them and nothing. Well, the compressor...

Replaced contactor and still won't go on.unless I keep the 2 buttons on the contactor [ 10 Answers ]

I replaced the contactor on outside unit it will not go on unless we hold the 2 button like things down. Once we let go it turns back off.. What could it be now

Replacing contactor on heating/air condenser [ 6 Answers ]

My outside heating/air unit will not turn on . I opened the panel and if I push this little spring loaded thing it contacts with a small circular object and the unit kicks on, when I release it turns off. It's a brand new unit, about 5 or 6 months old. Can I fix the problem myself. Repair guy can't...

Magnetic contactor [ 1 Answers ]

Is the computation of the load of magnetic contactors are the same with circuit breaker load calculation?

A/C condenser or Switch? [ 4 Answers ]

I think maybe the condesor motor is going bad, while a/c is on sometimes it spins for just a few seconds and shuts back off if I tap the top of the shroud it stays on, Sometimes it jerks all over trying to kick in? A/C is blowing hot air, and when motor is working it will blow cold. Yesterday in...


View more questions Search