    Coleman furnace anticipator settings for model # EB23B
    My husband just replaced our thermostat and he is unable to find the correct setting for the anticipator. Would you happen to know what this should be set on? Thanks!
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Nov 30, 2009, 06:31 PM
    No. But sometimes this setting or current draw number is on the wiring diagram on the furnace. Most if not all professionals use a meter to take a reading of the entire thermostat cable running to the thermostat to get a complete and accurate number to use for setting the heat anticipator.


    Here is a complete install manual for the EB series units. See page 9 for thermostat install and base anticipator setting. This will get you by but it is not as accurate as the use of a meter. Setting (0.4 AMPS)

    http://www.centraltrailer.com/resour...stall_eb_b.pdf
    will_teppie's Avatar
    will_teppie Posts: 3, Reputation: 1
    New Member
     
    #3

    Nov 30, 2009, 08:11 PM

    Thank you very much. Seems we have another problem now. The heat blows as long as it is on but, when you put it on auto it doesn't blow. You can hear the furnace trying to come on put it doesn't. Any ideas?
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #4

    Nov 30, 2009, 11:25 PM
    Look at figure 22 on page 16 of the above manual. You will see where the W (white) wire from the thermostat goes to the sequencer (H2). The sequencer controls not only the heat coils but also the blower motor in the automatic mode. So your problem could be the thermostat you messed with

    Or a bad connection between the thermostat W wire to the H2 terminal on the sequencer or the sequencer itself is defective.

    Usually it would be very rare for a sequencer to go bad at just the exact time a thermostat was changed so I would revisit all your wiring and hookups. If you have a meter and know how to use it you can check to see if 24 volts is at the H2 sequencer terminal when the system is in the heat mode. For the other meter leed just pick up ant good cabinet ground.
    JerryLehman's Avatar
    JerryLehman Posts: 1, Reputation: 1
    New Member
     
    #5

    Sep 4, 2011, 07:50 PM
    My Coleman EB23B fan motor doesn't run and outside heat pump doesn't run
    michellespraitz's Avatar
    michellespraitz Posts: 1, Reputation: 1
    New Member
     
    #6

    Oct 19, 2012, 05:35 AM
    What do I set the heat anticipator on when I am installing a new thermostat. This is for a coleman central electric furnace, model eb15c

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Coleman evcon furnace model no. DGU10014UB troubleshooting [ 11 Answers ]

Coleman furnace referenced in subject line ignites, getting gas, blower starts, runs for a couple minutes, unit shuts down, red LED light on board blinks ten times. Anyone know the code for this repair? I'm FREEZING! :(

Fan limit settings for a RHEEM Gas Furnace Model 3214-100FB [ 1 Answers ]

I have a RHEEM Gas Furnace Model 3214-100FB. My problem is that when the heat shuts off the fan keeps moving until all the hot air is removed from the vents. The fan then continues to blow until the house becomes cool again, which then causes the heat to have to come back on. What are the proper...

Coleman Electric Furnace Model 3500A816 [ 1 Answers ]

I am trying to help a friend with a heating problem. He has a Coleman Model 3500A816 electric furnace with a heat pump which are controlled by a Honeywell Chronotherm T8611G1103 thermostat. It appears that the heating elements are not being turned on because the air from the registers is not very...

Coleman Gas Furnace Model 7956-856 [ 1 Answers ]

I have an old furnace in a mobile home that kicks on and runs, but the blower fan keeps clicking on and off the whole time it runs when heating. What would cause that?

Coleman Presidential III Model # 7970A856 Furnace [ 6 Answers ]

Coleman Presidential III Model # 7970A856 Furnace The furnace runs for 1-2 minutes, then shuts off for about 30 seconds to a minute, then comes back on. It does that until it gets to the temp I set the thermostat to. I called the local technician, he said it was the fan Switch. He said check the...


View more questions Search