    RICK1861's Avatar
    RICK1861 Posts: 1, Reputation: 1
    New Member
     
    #1

    Jun 9, 2008, 08:03 PM
    Central air stays on all the time, even after inside fan turns off.
    I have an old Tempstar A/C unit that stays on after the blower turns off. I replaced the thermostat in the winter and it works fine with the heater (tuns on & off correctly). I removed the new thermostat from the system & the A/C unit still stays on. The only way I can get it to turn off is to turn the breaker off. This an OLD system so there are no circuit boards.
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Jun 9, 2008, 08:14 PM
    It could be a defective (contact welded) contactor in the outside unit. That will cause the outside unit to run all the time.

    You might have a short in the thermostat wiring keeping the ac on.
    There might be a a/c blower relay in the furnace that is defective causing the inside blower to run all the time.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Outside central air unit stays on when blower shuts off inside [ 1 Answers ]

I have a central heat and air unit. Why does my outside air conditioning unit stay on after my inside blower shuts off? It does not stay on every time the blower shuts off, but it does stay on a lot. It has been doing this for several years now.

Outside unit turns on. Rotates, inside unit turns on. Does not blow / suck. [ 4 Answers ]

Ok, we had a storm today, and I got home from work to find the house at a hot 75 degrees... the outside unit wouldn't turn on or work or anything... So, I went out and turned off ALL of the breakers, and then turned ALL of them back on... OK, the outside unit spins now... Then I went into...

Central AC not blowing inside, outside fan runs continuously. [ 2 Answers ]

My ac guy has added freon, cleaned the outside coil, replaced the inside fan motor, and replaced thermostat. The outside fan will kick on, but the inside fan doesn't kick on. If I shut the unit OFF, then back ON at the thermostat sometimes it will kick the inside air on and it will be fine. But,...

Central turns off by to soon [ 1 Answers ]

I'm finding that my central air turns off before it hits the desired temp set. The fan will continue to run on auto but the a/c unit turns off and then turns back on after 10-15min.

Heat won't come on and blower stays on all the time. [ 1 Answers ]

I have a problem with a furnace that the heater won't come on, "not at all", and the Blower it stays running all the time, can't turn it off unless disconnected. Before replacing the Circuit Board, I will appreciate if somebody tells me what other reasons are there that may cause this problem. ...


View more questions Search