Ask Experts Questions for FREE Help !
Ask
    verbalkint13's Avatar
    verbalkint13 Posts: 2, Reputation: 1
    New Member
     
    #1

    Jul 22, 2006, 12:17 PM
    Carrier to Hunter wiring
    I recently moved into an apartment with a very old Carrier thermostat (I think, too old to tell what it is).
    The wiring of this current unit is as follows:
    R
    O
    G1
    Y
    W2
    C

    I would like to exchange this unit for a Hunter programmable thermostat with the following terminals:
    G
    RC
    Y
    W
    RH

    This seems like a variation of a pretty common question, I would appreciate any help on this matter.
    tkrussell's Avatar
    tkrussell Posts: 9,659, Reputation: 725
    Uber Member
     
    #2

    Jul 22, 2006, 12:22 PM
    The new stat is not compatible with your heating/cooling system, since it appears to be a heat pump system. I get that is is a heat pump due to the O and W2 terminals, O being for a reversing valve, and W2 for auxiliary or emergency heat. Heat pumps will usually have electric heating elements built in to take over in the event the outdoor air does not have enough latent heat to draw from.

    You may want to look more closely at your entire system to see if there are any labels or wiring diagrams that will prove my point.
    verbalkint13's Avatar
    verbalkint13 Posts: 2, Reputation: 1
    New Member
     
    #3

    Jul 22, 2006, 06:46 PM
    Thanks for the information, I wasn't used to having a heat pump as I just moved from South Florida to North Carolina. I purchased an appropriate Honeywell thermostat and just finished the installation, it is working well so far.

    Thanks again.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Hunter Thermostat wiring [ 6 Answers ]

Hello! I seem to have "developed" a problem tonight. I just removed my old manual thermo and labeled the wiring accordingly. It looked the heat hot came into a spot labeled "4". Then it was jumpered to Rc. So when I hooked up the Hunter programmable 44360, there was already a jumper between Rc and...

Carrier 58STA090 - Hunter 44760 [ 1 Answers ]

I have a Carrier 58STA 090 with 8 colored wired and currently a Robertshaw 9200 thermostat. Just bought a Hunter 44760 thermostat and am having a hard time connecting: Robertshaw old connection: W White Y Yellow G Green Rc Red Carrier wires: 8

Hunter 44110 Programmable Thermostat Wiring HELP! [ 3 Answers ]

My current thermostat has the following six wires, hooked as follows: Orange to O Green to G Yellow to Y1 Red to R Black to C White to W1 I am attempting to install the Hunter Programmable thermostat, which only gives me 5 placements for wires:

Wiring issue with a Hunter Ceiling fan [ 2 Answers ]

Thanks in advance for anyone who can help me. I just moved into a brand new home and the Master Bedroom is pre-wired for a ceiling fan. It has two wall switches, one to control the light and one for the fan. The Hunter fan has a black, a white, a black/white and two green wires. The prewire...

White-Rodgers to new Hunter Thermostat (Wiring Help Please) [ 4 Answers ]

Hello, I have a new home, built in 2003, with Central Heat and Air. It's all run off electricity and is using a Lennox Model CB29M-41-1P heat pump. The WHITE ROGERS DIGITAL HEAT PUMP THERMOSTAT 1F89-211 used the following wires: White Red Brown Orange Yellow