Ask Experts Questions for FREE Help !
Ask
    scottlewis's Avatar
    scottlewis Posts: 1, Reputation: 1
    New Member
     
    #1

    Dec 18, 2009, 09:08 PM
    Carrier furnace trouble codes
    Carrier mvp 080 14 series 140 blower did not work replaced circuit board and blower module blower now works but led flashs 12 "blower calibration lockout"
    KC13's Avatar
    KC13 Posts: 2,556, Reputation: 99
    Ultra Member
     
    #2

    Dec 18, 2009, 11:11 PM
    Check out pg. 12, there's a little info there.
    Attached Images
  1. File Type: pdf om58-95.pdf (253.5 KB, 543 views)
  2. KISS's Avatar
    KISS Posts: 12,510, Reputation: 839
    Uber Member
     
    #3

    Dec 19, 2009, 12:25 PM

    OOps. p12 says call dealer for service for error #12

    The troubleshooting guide is here: http://www.xpedio.carrier.com/idc/gr...e=PdfHighlight

    Unfortunately, the trouble code 12 is "Blower on after power up" in that document not "Blower calibration error".

    Confused. Carrier docs aren't error free anyway.

    The error "Blower on after power up" is generally nothing to be concerned about. Generally means that there was a call for heat at the time the unit powered down.

    Since you replaced the board, you could potentially get a new set of error codes.

    If, indeed, it's a blower calibration error, then I would guess that's because the ECM motor isn't correct or the model plug from the old board wasn't installed. If the board is used and as no model plug, it assumes the last model used. If the board is new, it will not operate without an initial model plug.

    Each ECM motor MUST be exact because the RPM to CFM information is programmed into the motor based on the blowers mechanicals.

    The EXACT replacement must be used or the electronics module must be used from the old motor.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Carrier Weathermaker 8000 trouble codes? [ 11 Answers ]

Can anyone tell me where I can find a list of troubld codes for my Carrier Weathermaker 8000? Thanks. Charley

Goodman furnace trouble codes [ 4 Answers ]

I have a 5 year old goodman 92 that is giving me 5 blinks on the main circuit board. It goes through the start-up routine and after about three attempts the burners will stay on. What does that really mean?

Carrier furnace error codes [ 7 Answers ]

We have a Carrier 58PAV and the Red LED light is on. Furnace makes a high pitch noise when starting up. We are having trouble understanding the directions provided in the manual to do the component test. Instruction manual says to "To initiate the component test sequence shut OFF the room...

Carrier trouble codes [ 1 Answers ]

Hi I am having an issue with a Carrier furnace model #58STA90. It will not light and it gives a code of three short flashing led lights and then one long. I checked the igniter and did not see any cracks across it.


View more questions Search