    Carrier 58MVP Blower won't come on.
    Hello all,
    The blower on my Central AC will not come on. The display shows a code 41. It worked fine forever, but now fails to run the fan in heat, AC or even with just the fan on selection. Any ideas?

    Thanks!
    acetc's Avatar
    acetc Posts: 1,004, Reputation: 79
    Ultra Member
     
    #2

    Aug 21, 2007, 04:17 PM
    On the front of your furnace is a list of the codes , what does it say for code 41?
    ChipCarter's Avatar
    ChipCarter Posts: 3, Reputation: 1
    New Member
     
    #3

    Aug 21, 2007, 05:08 PM
    Quote Originally Posted by acetc
    On the front of your furnace is a list of the codes , what does it say for code 41?
    I've troubleshot it down to the blower motor or the circuit board/CPU. I already know what the code 41 is telling me, I was looking for a more detailed answer though. Is there anyway to jumper the motor to tell if it will spool up? The tech guys are telling me a capacitor is invloved, but I don't see it in the schematic... I found a troubleshooting manual here:

    http://www.comfortproducts.com/downl...0%20series.pdf
    acetc's Avatar
    acetc Posts: 1,004, Reputation: 79
    Ultra Member
     
    #4

    Aug 21, 2007, 05:33 PM
    You are right , there is no capacitor because this is a variable speed DC motor, the only thing you can do is go to page 27 and 28 of your instruction manual and take it step by step in order to determine what is bad, there is no way to jumper something to make it run, but I will say this that I have found most of the time the problem is the modual on the motor (this bolts to the back of the motor that's why it is so long) Check for date of installation (They have five years warranty) If you don't know date , look at the serial number. The first two numbers is the week and the second two numbers are the year it was manufactured. The motor and the modual can be replaced independently of one another, (Very expensive) Good luck, Mike
    ChipCarter's Avatar
    ChipCarter Posts: 3, Reputation: 1
    New Member
     
    #5

    Aug 21, 2007, 05:40 PM
    Quote Originally Posted by acetc
    You are right , there is no capacitor because this is a variable speed DC motor, the only thing you can do is go to page 27 and 28 of your instruction manual and take it step by step in order to determine what is bad, there is no way to jumper something to make it run, but I will say this that i have found most of the time the problem is the modual on the motor (this bolts to the back of the motor thats why it is so long) Check for date of installation (They have five years warranty) If you don't know date , look at the serial number. The first two numbers is the week and the second two numbers are the year it was manufactured. The motor and the modual can be replaced independently of one another, (Very expensive) Good luck, Mike
    Mike,
    Thanks for the input! Using the troubleshooting guide I ran it down to change the motor. I've got a carrier guy coming by tomorrow to confirm for $69... I will do the work, I just want to see if he comes up with the same answer. Any ideas on web based supply houses for the motor or module?

    Thanks,
    Chip Carter
    acetc's Avatar
    acetc Posts: 1,004, Reputation: 79
    Ultra Member
     
    #6

    Aug 21, 2007, 05:48 PM
    This part ,either modual or motor has to come from Carrier, so try to purchase direct to save money since you are changing it yourself. I had a modual go out on my furnace a few years back and it cost me wholesale over two hundred dollars and I think the motor is over three hundred, as you have seen there is a long list of things to check to be sure what's wrong.. Good luck, mike

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Carrier furnace blower motor won't turn off [ 5 Answers ]

I have a Carrier central air and furnace(furnace model 58GS050-3), it was built around November, 1985. It has carrier air conditioner indoor cooling coils box model 28AC030-911 laid on top of the furnace. Everything was working until one week ago. Now with the thermostat off and the fan set to...

Carrier 58GS125-2, Burner shuts down after 10 Sec, no Blower [ 6 Answers ]

I am trying to fix a Carrier Model 58GS125-2 with spark ignition. Thermostat Switches on Heat Spark Starts Pilot Lights After about 10 seconds Burner Starts After about 10 more second Burner goes out Pilot stays lit and burner keeps cyling on and off with no blower. Extra info. 3 Wire...

Air conditioner, blower fan speed with carrier furnace [ 2 Answers ]

The fan speed does not adjust when the air conditioner is on . Is this normal ? If I turn the set temp up high enough the air conditioner turns off and the adjustability returns. Auto, low, medium and high all work. When I set the temperature back down so the air conditioner turns back on the...

Carrier Blower Control board knocked out by lightning [ 2 Answers ]

I would like to know how to hard wire the blower on my Carrier AC unit until I can get a new part for the blower control board? Also where can I shop for this board? Following a lighting strike, the fan stopped blowing even though the outside AC unit still ran. Thanks

No heat, blower runs constantly, carrier gas furnace [ 7 Answers ]

This am we I got up the blower on my carrier series 100 gas furnace (approx 10 years old)was running and blowing out cold air. Even with the thermostat turned to off the blower runs constantly. The only way to stop the blower from running is to turn the switch on the side of the furnace to off or...


View more questions Search