Ask Experts Questions for FREE Help !
Ask
    Namebejed7's Avatar
    Namebejed7 Posts: 1, Reputation: 1
    New Member
     
    #1

    Sep 10, 2007, 11:42 AM
    Capacitor for Blower Motor
    My A/C fan quit working and I tried to replace the capacitor first with no results. I then purchased the blower motor but it has 4 wires instead of the 3 that my old motor had. I have a black wire, yellow, and 2 browns. My old motor had black, yellow, and 1 brown. My old motor was wired into a 5/35 capacitor and had that rating on it, it was wired as yellow to spade terminal, black to circuit board labeled OF 2 and brown to capacitor. My new motor is only labeled as a 5 rating instead of 5/35. My capacitor does have 2 terminals for where the brown wire on the old motor plugged in.

    My question is, can I plug both brown wires into the last part of the capacitor (oval 5/35, 370) or do I need to get a specific capacitor for the fan?

    Thanks in advance for all advice.

    Jed
    acetc's Avatar
    acetc Posts: 1,004, Reputation: 79
    Ultra Member
     
    #2

    Sep 10, 2007, 05:57 PM
    Use the new capacitor, connect the two brown wires to the new capacitor, one wire on each side and no other wires (2 brown to capacitor only) Connect the yellow to the same place on the old capacitor (leave old capacitor in place for compressor) Connect black to where old black was connected to. Good luck, Mike
    joellon50's Avatar
    joellon50 Posts: 2, Reputation: 1
    New Member
     
    #3

    Apr 1, 2008, 08:31 AM
    Comment on acetc's post
    Outstanding

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Blower motor or capacitor? [ 10 Answers ]

Hi. Yesterday the blower motor for my central air did not initially come on when tripped by the thermostat. It did come on in a subdued fashion a few minutes later. When I turned it off after a minute or so, the motor shaft was quite hot and there was an electrical smell near the unit. The...

Motor or Capacitor? [ 2 Answers ]

How can you rule out a bad capacitor? Is the only way by ohms?

Capacitor size change for blower motor [ 2 Answers ]

general electric motor, direct drive, 5uf cap First check: when heat exchanger reached temp, the relay clicked but the blower fan just hummed. The bearings seem OK as a slight push causes a rotation that continues for some time. Also, such a slight push causes it to run fine for the cycle. ...

Blower motor capacitor? [ 20 Answers ]

I've got a Lennox G12 series furnace and the blower seems to have stopped working. I read a few posts and saw a reply mention giving the fan a little push start while the burners kicked on. I did this and the blower started up. I can hear the "current" feeding the motor but it seems to be having...

Ceiling Fan - Motor Start Capacitor [ 2 Answers ]

I have a Hampton Bay ceiling fan whose motor fails to self-start. The fan has three speeds. All three speeds work fine if I hand spin the blades, starting at low speed of course. The fan has a remote unit. Once I hand start the fan the remote allows me to change speeds up and down and turn off the...


View more questions Search